Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: translateModel(Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|chi.sta_a2.T|chi.sta_b2.T|chi.TSet|chi.QEva_flow|chi.QCon_flow|chi.P|chi.dp1|chi.dp2|chi.COP_nominal|chi.COP|chi.port_a1.m_flow|chi.port_b1.m_flow",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature") translateModel(Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|chi.sta_a2.T|chi.sta_b2.T|chi.TSet|chi.QEva_flow|chi.QCon_flow|chi.P|chi.dp1|chi.dp2|chi.COP_nominal|chi.COP|chi.port_a1.m_flow|chi.port_b1.m_flow",fileNamePrefix="Buildings_maint.7.0.x_Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.377/1.377, allocations: 251.9 MB / 266.9 MB, free: 11.05 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001171/0.00117, allocations: 184.8 kB / 326.5 MB, free: 2.238 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.815/1.815, allocations: 205.4 MB / 0.5775 GB, free: 20.23 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008539/0.0008537, allocations: 93.83 kB / 0.6821 GB, free: 12.87 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0003496/0.0003496, allocations: 9.469 kB / 0.7962 GB, free: 135.1 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2467/0.247, allocations: 106.3 MB / 0.9001 GB, free: 63.92 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.9823/1.229, allocations: 414.9 MB / 1.305 GB, free: 1.531 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002559/1.23, allocations: 91.14 kB / 1.305 GB, free: 1.484 MB / 0.8073 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_HighTemperature Notification: Performance of FrontEnd: time 0.1654/1.395, allocations: 82.75 MB / 1.386 GB, free: 10.48 MB / 0.8855 GB