Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|noGai.bui.zon.TAir|radOnl.bui.zon.TAir|conOnl.bui.zon.TAir|latOnl.bui.zon.TAir|noGai.bui.zon.TRad|radOnl.bui.zon.TRad|conOnl.bui.zon.TRad|latOnl.bui.zon.TRad|noGai.bui.zon.phi|radOnl.bui.zon.phi|conOnl.bui.zon.phi|latOnl.bui.zon.phi|noGai.bui.zon.ports.1..Xi_outflow.1.|radOnl.bui.zon.ports.1..Xi_outflow.1.|conOnl.bui.zon.ports.1..Xi_outflow.1.|latOnl.bui.zon.ports.1..Xi_outflow.1.",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain") translateModel(Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|noGai.bui.zon.TAir|radOnl.bui.zon.TAir|conOnl.bui.zon.TAir|latOnl.bui.zon.TAir|noGai.bui.zon.TRad|radOnl.bui.zon.TRad|conOnl.bui.zon.TRad|latOnl.bui.zon.TRad|noGai.bui.zon.phi|radOnl.bui.zon.phi|conOnl.bui.zon.phi|latOnl.bui.zon.phi|noGai.bui.zon.ports.1..Xi_outflow.1.|radOnl.bui.zon.ports.1..Xi_outflow.1.|conOnl.bui.zon.ports.1..Xi_outflow.1.|latOnl.bui.zon.ports.1..Xi_outflow.1.",fileNamePrefix="Buildings_latest_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.453/2.453, allocations: 393.5 MB / 408.4 MB, free: 11.07 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001812/0.001812, allocations: 186.8 kB / 0.4902 GB, free: 2.258 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.897/1.897, allocations: 223.1 MB / 0.7992 GB, free: 14.76 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001256/0.001256, allocations: 112.6 kB / 0.9396 GB, free: 1.934 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0004882/0.0004883, allocations: 15.56 kB / 1.09 GB, free: 216.4 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4729/0.4734, allocations: 143 MB / 1.229 GB, free: 105.8 MB / 0.823 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.299/5.773, allocations: 1.96 GB / 3.189 GB, free: 35.91 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003478/5.773, allocations: 104 kB / 3.189 GB, free: 35.8 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/ThermalZones/EnergyPlus_9_6_0/BaseClasses/ThermalZoneAdapter.mo:101:3-131:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.InternalGain Notification: Performance of FrontEnd: time 1.83/7.603, allocations: 430.5 MB / 3.609 GB, free: 73.61 MB / 1.167 GB