Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 10.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|ahu.port_a1.m_flow|ahu.port_a2.m_flow|ahu.cooCoi.Q1_flow|ahu.cooCoi.Q2_flow|ahu.cooCoi.QSen2_flow|ahu.cooCoi.QLat2_flow|temSou_2.y|temSenWat1.T|temSenWat2.T|temSenAir2.T",fileNamePrefix="Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop") translateModel(Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|ahu.port_a1.m_flow|ahu.port_a2.m_flow|ahu.cooCoi.Q1_flow|ahu.cooCoi.Q2_flow|ahu.cooCoi.QSen2_flow|ahu.cooCoi.QLat2_flow|temSou_2.y|temSenWat1.T|temSenWat2.T|temSenAir2.T",fileNamePrefix="Buildings_latest_Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/package.mo): time 2.282/2.282, allocations: 393.5 MB / 408.4 MB, free: 10.98 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001052/0.001053, allocations: 179.9 kB / 0.4902 GB, free: 2.215 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.506/1.506, allocations: 223.2 MB / 0.7992 GB, free: 14.69 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0009266/0.0009266, allocations: 112.1 kB / 0.9396 GB, free: 1.828 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0003628/0.0003626, allocations: 10.28 kB / 1.09 GB, free: 216.2 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2898/0.2901, allocations: 143 MB / 1.229 GB, free: 105.7 MB / 0.823 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.14/6.43, allocations: 2.366 GB / 3.595 GB, free: 25.61 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003795/6.43, allocations: 113.5 kB / 3.595 GB, free: 25.54 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/BaseClasses/Euler/getPeak.mo:9:3-10:49:writable] Warning: Component peak in env: Buildings.Fluid.Movers.BaseClasses.Euler.getPeak has the same name as its type Buildings.Fluid.Movers.BaseClasses.Euler.peak. This is forbidden by Modelica specification and may lead to lookup errors. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.0.0-master/Fluid/Movers/Data/Generic.mo:90:3-92:29:writable] Error: Class Buildings.Fluid.Movers.BaseClasses.Euler.getPeak not found in scope Buildings.Fluid.Movers.Data.Generic$ahu$perFan (looking for a function or record). Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Equipment.Validation.CoolingCoilHumidifyingHeating_OpenLoop Notification: Performance of FrontEnd: time 1.622/8.052, allocations: 425.4 MB / 4.01 GB, free: 72.07 MB / 1.167 GB