Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_9_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package Buildings with version 9.1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo) Running command: translateModel(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|grid.P.real|grid.P.apparent|pvSimple.load.S.1.|pvSimple.load.S.2.|RL.S.1.|RL.S.2.|pvOriented.panel.load.S.1.|pvOriented.panel.load.S.2.",fileNamePrefix="Buildings_9_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels") translateModel(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,tolerance=1e-06,outputFormat="mat",numberOfIntervals=5000,variableFilter="time|grid.P.real|grid.P.apparent|pvSimple.load.S.1.|pvSimple.load.S.2.|RL.S.1.|RL.S.2.|pvOriented.panel.load.S.1.|pvOriented.panel.load.S.2.",fileNamePrefix="Buildings_9_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/package.mo): time 2.301/2.301, allocations: 390.3 MB / 405.3 MB, free: 13.53 MB / 314.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001124/0.001124, allocations: 183.3 kB / 498.1 MB, free: 5.754 MB / 394.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.766/1.766, allocations: 223.2 MB / 0.7949 GB, free: 17.79 MB / 0.5573 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.0008802/0.0008802, allocations: 98.72 kB / 0.9346 GB, free: 6.113 MB / 0.6823 GB Notification: Performance of FrontEnd - loaded program: time 0.0004366/0.0004366, allocations: 14.69 kB / 1.084 GB, free: 221.3 MB / 0.823 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.331/0.3315, allocations: 142.3 MB / 1.223 GB, free: 114.2 MB / 0.823 GB Notification: Performance of FrontEnd - scodeFlatten: time 4.698/5.03, allocations: 1.765 GB / 2.988 GB, free: 220.2 MB / 1.167 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003128/5.03, allocations: 106.5 kB / 2.988 GB, free: 220.2 MB / 1.167 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.1-maint.9.1.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.1684/5.199, allocations: 73.49 MB / 3.059 GB, free: 157.6 MB / 1.167 GB