Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain") translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.8/1.8, allocations: 292.6 MB / 307.6 MB, free: 5.188 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001165/0.001165, allocations: 177 kB / 377.1 MB, free: 1.508 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.842/1.842, allocations: 205.4 MB / 0.6367 GB, free: 8.633 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001087/0.001086, allocations: 85.48 kB / 0.751 GB, free: 63.18 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004037/0.0004037, allocations: 8 kB / 0.8748 GB, free: 11.18 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3597/0.3602, allocations: 116.3 MB / 0.9884 GB, free: 6.73 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.386/6.746, allocations: 2.113 GB / 3.102 GB, free: 67.68 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002908/6.746, allocations: 101 kB / 3.102 GB, free: 67.59 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain Notification: Performance of FrontEnd: time 1.468/8.215, allocations: 426.3 MB / 3.518 GB, free: 15.98 MB / 0.948 GB