Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.1.4 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950") translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_8_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/package.mo): time 1.739/1.739, allocations: 292.6 MB / 307.5 MB, free: 5.211 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001203/0.001203, allocations: 177 kB / 377.1 MB, free: 1.512 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.724/1.724, allocations: 205.4 MB / 0.6367 GB, free: 8.594 MB / 474.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00087/0.00087, allocations: 92.7 kB / 0.751 GB, free: 63.2 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0003564/0.0003564, allocations: 8 kB / 0.8748 GB, free: 11.18 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3191/0.3194, allocations: 116.3 MB / 0.9884 GB, free: 6.723 MB / 0.7136 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.009/7.328, allocations: 2.252 GB / 3.24 GB, free: 285.6 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004201/7.329, allocations: 117.8 kB / 3.241 GB, free: 285.6 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:199:3-207:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950 Notification: Performance of FrontEnd: time 0.4867/7.816, allocations: 228.5 MB / 3.464 GB, free: 114 MB / 0.948 GB