Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain.conf.json loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.0 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo) Running command: translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain") translateModel(Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_8.0.0_Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/package.mo): time 2.571/2.571, allocations: 287.5 MB / 302.4 MB, free: 8.211 MB / 234.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001488/0.001488, allocations: 177.1 kB / 371 MB, free: 10.77 MB / 298.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.069/2.069, allocations: 205.4 MB / 0.6297 GB, free: 10.53 MB / 458.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001153/0.001152, allocations: 90 kB / 0.743 GB, free: 6.516 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0005191/0.0005188, allocations: 15.75 kB / 0.8658 GB, free: 140.7 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2326/0.2331, allocations: 115.3 MB / 0.9784 GB, free: 28.29 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.824/7.057, allocations: 2.112 GB / 3.091 GB, free: 157 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003316/7.058, allocations: 97.7 kB / 3.091 GB, free: 157 MB / 0.948 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.0/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Validation.ThermalZone.InternalGain Notification: Performance of FrontEnd: time 2.112/9.17, allocations: 426.7 MB / 3.507 GB, free: 111.6 MB / 0.948 GB