Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.119/2.119, allocations: 251.1 MB / 266.1 MB, free: 11.63 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001682/0.001682, allocations: 177.9 kB / 325.6 MB, free: 2.828 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.381/2.381, allocations: 205.4 MB / 0.5766 GB, free: 21.12 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001198/0.001197, allocations: 98.81 kB / 0.6811 GB, free: 14.01 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004909/0.0004909, allocations: 12.03 kB / 0.7951 GB, free: 135.7 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2309/0.2314, allocations: 106.3 MB / 0.8989 GB, free: 65.94 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.591/7.822, allocations: 2.333 GB / 3.232 GB, free: 179.7 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000386/7.822, allocations: 105.3 kB / 3.232 GB, free: 179.6 MB / 0.8855 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.SampledModel.OnlyExteriorWallWithWindowInteriorShade Notification: Performance of FrontEnd: time 2.682/10.5, allocations: 465.6 MB / 3.686 GB, free: 77.35 MB / 0.8855 GB