Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.SingleZoneFloorWithHeating.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.SingleZoneFloorWithHeating,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.SingleZoneFloorWithHeating") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.236/2.236, allocations: 251.1 MB / 266.1 MB, free: 11.57 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001532/0.001532, allocations: 186 kB / 325.6 MB, free: 2.82 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.33/2.33, allocations: 205.4 MB / 0.5766 GB, free: 20.73 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001136/0.001136, allocations: 100.6 kB / 0.6811 GB, free: 13.56 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004876/0.0004876, allocations: 18.97 kB / 0.7951 GB, free: 135.7 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2155/0.216, allocations: 106.3 MB / 0.8989 GB, free: 65.43 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.576/7.793, allocations: 2.428 GB / 3.327 GB, free: 80.11 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003187/7.793, allocations: 100.1 kB / 3.327 GB, free: 80.05 MB / 0.8855 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Examples/VAVReheat/ThermalZones/Floor.mo:235:7-235:29:writable] Error: Type mismatch in binding material = Buildings.HeatTransfer.Data.Solids.Concrete$flo$matCon(0.1, 1.311, 836, 2240.0, 0.07627765064836003, 5, 2, false, 331.4, 119.5159318710878, 1.803197523703799, 293.15, 293.15, 0.0, false, false), expected subtype of record Buildings.HeatTransfer.Data.BaseClasses.Material Real(quantity = "Length", unit = "m") x; Real(quantity = "ThermalConductivity", unit = "W/(m.K)") k; Real(quantity = "SpecificHeatCapacity", unit = "J/(kg.K)") c; Real(quantity = "Density", unit = "kg/m3", displayUnit = "g/cm3", min = 0.0) d; Real(unit = "m2.K/W") R; Integer(min = 0) nStaRef; Integer(min = 1) nSta; Boolean steadyState; Real piRef; Real piMat; Real(min = 0.0) nStaReal; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") TSol; Real(quantity = "ThermodynamicTemperature", unit = "K", min = 0.0, start = 288.15, nominal = 300.0, displayUnit = "degC") TLiq; Real(quantity = "SpecificEnergy", unit = "J/kg") LHea; Boolean ensureMonotonicity; Boolean phasechange; end Buildings.HeatTransfer.Data.BaseClasses.Material;, got type record Buildings.HeatTransfer.Data.Solids.Concrete$flo$matCon Real x; Real k; Integer c; Real d; Real R; Integer nStaRef; Integer nSta; Boolean steadyState; Real piRef; Real piMat; Real nStaReal; Real TSol; Real TLiq; Real LHea; Boolean ensureMonotonicity; Boolean phasechange; end Buildings.HeatTransfer.Data.Solids.Concrete$flo$matCon;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.SingleZoneFloorWithHeating Notification: Performance of FrontEnd: time 11.03/18.82, allocations: 1.957 GB / 5.284 GB, free: 80.95 MB / 0.9636 GB