Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.202/2.202, allocations: 251.1 MB / 266.1 MB, free: 11.55 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001559/0.001559, allocations: 177.7 kB / 325.6 MB, free: 2.805 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.368/2.368, allocations: 205.4 MB / 0.5766 GB, free: 21.05 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00119/0.00119, allocations: 100.5 kB / 0.6811 GB, free: 13.97 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0006241/0.0006242, allocations: 13.12 kB / 0.7951 GB, free: 135.9 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2275/0.2282, allocations: 106.3 MB / 0.8989 GB, free: 65.89 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.49/7.718, allocations: 2.336 GB / 3.235 GB, free: 175.1 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003491/7.719, allocations: 101.9 kB / 3.235 GB, free: 175.1 MB / 0.8855 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.Initialization.MixedAir Notification: Performance of FrontEnd: time 1.886/9.605, allocations: 286.2 MB / 3.515 GB, free: 208.6 MB / 0.8855 GB