Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.135/2.135, allocations: 251.1 MB / 266.1 MB, free: 11.63 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001593/0.001593, allocations: 197.8 kB / 325.6 MB, free: 2.836 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.294/2.294, allocations: 205.4 MB / 0.5766 GB, free: 21.08 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001284/0.001284, allocations: 94.42 kB / 0.6811 GB, free: 14.01 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004881/0.000488, allocations: 16.47 kB / 0.7951 GB, free: 135.8 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.221/0.2216, allocations: 106.3 MB / 0.8989 GB, free: 65.92 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.52/7.741, allocations: 2.367 GB / 3.266 GB, free: 145.1 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005237/7.742, allocations: 117.4 kB / 3.266 GB, free: 145 MB / 0.8855 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:198:3-206:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950 Notification: Performance of FrontEnd: time 1.4/9.142, allocations: 223.8 MB / 3.484 GB, free: 216.8 MB / 0.8855 GB