Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case640.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case640,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case640") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.228/2.228, allocations: 251.1 MB / 266.1 MB, free: 11.62 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001522/0.001522, allocations: 188.2 kB / 325.6 MB, free: 2.828 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.405/2.405, allocations: 205.4 MB / 0.5766 GB, free: 21.09 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001169/0.001168, allocations: 102.2 kB / 0.6811 GB, free: 14 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0006682/0.0006684, allocations: 11.69 kB / 0.7951 GB, free: 135.8 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2146/0.2153, allocations: 106.3 MB / 0.8989 GB, free: 65.91 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.4/7.616, allocations: 2.365 GB / 3.264 GB, free: 146.5 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005935/7.616, allocations: 113.9 kB / 3.264 GB, free: 146.5 MB / 0.8855 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:198:3-206:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case640 Notification: Performance of FrontEnd: time 1.404/9.021, allocations: 226.9 MB / 3.486 GB, free: 216.2 MB / 0.8855 GB