Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.084/2.084, allocations: 251.1 MB / 266.1 MB, free: 11.62 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001622/0.001622, allocations: 183.9 kB / 325.6 MB, free: 2.848 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.324/2.324, allocations: 205.4 MB / 0.5766 GB, free: 20.74 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001165/0.001165, allocations: 88.67 kB / 0.6811 GB, free: 13.61 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004813/0.0004814, allocations: 11.94 kB / 0.7951 GB, free: 135.6 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2167/0.2172, allocations: 106.3 MB / 0.8989 GB, free: 65.46 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.484/7.702, allocations: 2.366 GB / 3.265 GB, free: 143.7 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004618/7.702, allocations: 119.5 kB / 3.265 GB, free: 143.6 MB / 0.8855 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:198:3-206:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case620 Notification: Performance of FrontEnd: time 1.384/9.086, allocations: 227 MB / 3.486 GB, free: 215.8 MB / 0.8855 GB