Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.164/2.164, allocations: 251.1 MB / 266.1 MB, free: 11.62 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001622/0.001621, allocations: 185.9 kB / 325.6 MB, free: 2.832 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.333/2.333, allocations: 205.4 MB / 0.5766 GB, free: 20.75 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001186/0.001185, allocations: 100.6 kB / 0.6811 GB, free: 13.59 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004897/0.0004896, allocations: 12.5 kB / 0.7951 GB, free: 135.5 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2235/0.224, allocations: 106.3 MB / 0.8989 GB, free: 65.45 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.423/7.647, allocations: 2.365 GB / 3.264 GB, free: 144.1 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004428/7.647, allocations: 124.3 kB / 3.264 GB, free: 144 MB / 0.8855 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/ThermalZones/Detailed/Validation/BESTEST/Cases6xx/Case600FF.mo:198:3-206:69:writable] Error: Variable staRes: In modifier (minT(Min = 254.35), class or component Min), class or component minT not found in . Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case610 Notification: Performance of FrontEnd: time 1.43/9.077, allocations: 226.9 MB / 3.486 GB, free: 216.3 MB / 0.8855 GB