Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_Dynamic.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_Dynamic,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_Dynamic") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.112/2.112, allocations: 251.1 MB / 266.1 MB, free: 11.62 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001506/0.001505, allocations: 176.5 kB / 325.6 MB, free: 2.816 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.284/2.284, allocations: 205.4 MB / 0.5766 GB, free: 21.09 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001177/0.001177, allocations: 100 kB / 0.6811 GB, free: 14 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004741/0.0004742, allocations: 15.5 kB / 0.7951 GB, free: 135.5 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1982/0.1987, allocations: 106.3 MB / 0.8989 GB, free: 65.94 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.259/1.458, allocations: 417.2 MB / 1.306 GB, free: 1.922 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003565/1.459, allocations: 98.55 kB / 1.306 GB, free: 1.871 MB / 0.8073 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-20:84:writable] Error: Class Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope Buildings.Fluid.HeatPumps.Compressors.ScrollCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.ScrollWaterToWater_Dynamic Notification: Performance of FrontEnd: time 1.064/2.523, allocations: 120.5 MB / 1.424 GB, free: 209.3 MB / 0.8855 GB