Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.068/2.068, allocations: 251.1 MB / 266.1 MB, free: 11.61 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001579/0.001578, allocations: 185.3 kB / 325.6 MB, free: 2.816 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.297/2.297, allocations: 205.4 MB / 0.5766 GB, free: 20.76 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.00114/0.00114, allocations: 94.88 kB / 0.6811 GB, free: 13.57 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004801/0.0004801, allocations: 15.52 kB / 0.7951 GB, free: 135.5 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2159/0.2164, allocations: 106.2 MB / 0.8989 GB, free: 65.43 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.21/1.426, allocations: 414.8 MB / 1.304 GB, free: 4.25 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003054/1.426, allocations: 96.25 kB / 1.304 GB, free: 4.199 MB / 0.8073 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL Notification: Performance of FrontEnd: time 0.3295/1.756, allocations: 83.95 MB / 1.386 GB, free: 11.61 MB / 0.8855 GB