Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.311/2.311, allocations: 251.1 MB / 266.1 MB, free: 11.63 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001546/0.001546, allocations: 180.3 kB / 325.6 MB, free: 2.828 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.358/2.358, allocations: 205.4 MB / 0.5766 GB, free: 20.72 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001594/0.001594, allocations: 90.42 kB / 0.6811 GB, free: 13.6 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0006391/0.0006392, allocations: 12.12 kB / 0.7951 GB, free: 135.6 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2104/0.2111, allocations: 106.3 MB / 0.8989 GB, free: 65.46 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.97/2.181, allocations: 0.4941 GB / 1.393 GB, free: 224.1 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000395/2.182, allocations: 107 kB / 1.393 GB, free: 224.1 MB / 0.8855 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Streams.mo:212:5-212:61:writable] Warning: Unused input variable nrow in function .Modelica.Utilities.Streams.readRealMatrix. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Utilities/Streams.mo:213:5-213:64:writable] Warning: Unused input variable ncol in function .Modelica.Utilities.Streams.readRealMatrix. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Interfaces/LumpedVolumeDeclarations.mo:3:15-12:61:writable] Notification: From here: [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Geothermal/Borefields/Validation/ConstantHeatInjection_100Boreholes.mo:51:3-63:73:writable] Error: component hea contains the definition of a partial class Medium. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes Notification: Performance of FrontEnd: time 24.31/26.49, allocations: 4.277 GB / 5.67 GB, free: 80.82 MB / 0.9794 GB