Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.172/2.172, allocations: 251.1 MB / 266.1 MB, free: 11.62 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001562/0.001562, allocations: 189.9 kB / 325.6 MB, free: 2.836 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.383/2.383, allocations: 205.4 MB / 0.5766 GB, free: 20.75 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001151/0.001151, allocations: 97.16 kB / 0.6811 GB, free: 13.62 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0006162/0.0006163, allocations: 9.094 kB / 0.7951 GB, free: 135.6 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2107/0.2114, allocations: 106.3 MB / 0.8989 GB, free: 65.5 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.257/1.468, allocations: 417.2 MB / 1.306 GB, free: 1.402 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003013/1.469, allocations: 100.9 kB / 1.306 GB, free: 1.348 MB / 0.8073 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Chillers/Validation/CarnotVerifyCOP.mo:42:3-59:69:writable] Error: Variable chi_TEva: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi_TEva: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.CarnotVerifyCOP Notification: Performance of FrontEnd: time 1.141/2.61, allocations: 149.4 MB / 1.452 GB, free: 293.7 MB / 0.8855 GB