Running: ./testmodel.py --libraries=/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer.conf.json Using package ModelicaServices with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.1 (/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo) Running command: translateModel(Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_7.0.0_Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer") Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/package.mo): time 2.167/2.167, allocations: 251.1 MB / 266.1 MB, free: 11.57 MB / 218.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001523/0.001523, allocations: 184.5 kB / 325.6 MB, free: 2.812 MB / 250.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.306/2.306, allocations: 205.4 MB / 0.5766 GB, free: 21.08 MB / 426.7 MB Notification: Performance of loadFile(/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001114/0.001114, allocations: 104.3 kB / 0.6811 GB, free: 14 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004723/0.0004724, allocations: 9.062 kB / 0.7951 GB, free: 135.6 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.208/0.2085, allocations: 106.3 MB / 0.8989 GB, free: 65.94 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 8.413/8.621, allocations: 2.662 GB / 3.561 GB, free: 176.6 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003821/8.622, allocations: 114.9 kB / 3.561 GB, free: 176.6 MB / 0.8855 GB [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[2].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumCW[1].pressure.V_flow={0.006940000000000001, 0.02082, 0.0347, 0.04164}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[2].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumPri[1].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumSec[2].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Fluid/Movers/Data/Generic.mo:7:3-11:47:writable] Error: Array equation has unknown size in perPumSec[1].pressure.V_flow={0.00366, 0.01098, 0.0183, 0.02196}. [/var/lib/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.1/Applications/DataCenters/ChillerCooled/Examples/BaseClasses/PartialDataCenter.mo:121:5-121:17:writable] Error: Type mismatch in binding hydraulicEfficiency = Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency({0}, {0.7}), expected subtype of record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters Real(min = 0.0, quantity = "VolumeFlowRate", unit = "m3/s")[1] V_flow; Real(max = 1.0, quantity = "Efficiency", unit = "1", min = 0.0)[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters;, got type record Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency Integer[1] V_flow; Real[1] eta; end Buildings.Fluid.Movers.BaseClasses.Characteristics.efficiencyParameters$perPumCW$hydraulicEfficiency;. Error: Error occurred while flattening model Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer Notification: Performance of FrontEnd: time 5.91/14.53, allocations: 1.113 GB / 4.675 GB, free: 83.23 MB / 0.9011 GB