Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950,tolerance=1e-06,outputFormat="empty",numberOfIntervals=17520,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.009412/0.009411, allocations: 110.6 kB / 15.05 MB, free: 5.961 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001132/0.001132, allocations: 184.1 kB / 15.94 MB, free: 5.926 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 2.014/2.014, allocations: 194.6 MB / 211.3 MB, free: 11.26 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.183/2.183, allocations: 236.2 MB / 492.6 MB, free: 11.37 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0005081/0.0005083, allocations: 15.98 kB / 0.587 GB, free: 2.16 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5497/0.5502, allocations: 98.72 MB / 0.6834 GB, free: 16.76 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.669/6.219, allocations: 2.351 GB / 3.034 GB, free: 93.21 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000429/6.22, allocations: 120 kB / 3.035 GB, free: 93.1 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/Outside.mo:28:3-31:49:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource.mo:38:3-40:49:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg", final quantity = Medium.substanceNames) "Needed to connect to conditional connector" second element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg") "Needed to connect to conditional connector" Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950 Notification: Performance of FrontEnd: time 0.865/7.085, allocations: 120.1 MB / 3.152 GB, free: 212.3 MB / 0.823 GB