Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.009018/0.009018, allocations: 110.1 kB / 15.05 MB, free: 6.051 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001141/0.001141, allocations: 190.7 kB / 15.95 MB, free: 5.973 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 1.826/1.826, allocations: 194.6 MB / 211.3 MB, free: 11.06 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.179/2.179, allocations: 236.2 MB / 492.6 MB, free: 11.34 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004796/0.0004797, allocations: 12 kB / 0.5869 GB, free: 2.188 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5888/0.5893, allocations: 98.7 MB / 0.6833 GB, free: 16.75 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.72/6.309, allocations: 2.317 GB / 3.001 GB, free: 82.57 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002693/6.31, allocations: 105.4 kB / 3.001 GB, free: 82.51 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:248:11-248:38:writable] Error: Type mismatch in binding ove = Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove(0, 0, 0, 0, false), expected subtype of record Buildings.ThermalZones.Detailed.BaseClasses.Overhang Real(min = 0.0, quantity = "Length", unit = "m") wL; Real(min = 0.0, quantity = "Length", unit = "m") wR; Real(min = 0.0, quantity = "Length", unit = "m") dep; Real(min = 0.0, quantity = "Length", unit = "m") gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang;, got type record Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove Integer wL; Integer wR; Integer dep; Integer gap; Boolean haveOverhang; end Buildings.ThermalZones.Detailed.BaseClasses.Overhang$roo$datConExtWin$ove;. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Examples.FFD.ForcedConvection Notification: Performance of FrontEnd: time 1.4/7.71, allocations: 267.7 MB / 3.262 GB, free: 145.9 MB / 0.823 GB