Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.00913/0.009129, allocations: 109.7 kB / 15.05 MB, free: 5.961 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001101/0.0011, allocations: 186.9 kB / 15.95 MB, free: 5.926 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 1.902/1.902, allocations: 194.6 MB / 211.3 MB, free: 11.04 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.186/2.186, allocations: 236.2 MB / 492.6 MB, free: 11.36 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004681/0.0004682, allocations: 19.92 kB / 0.5869 GB, free: 2.164 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.6231/0.6236, allocations: 98.7 MB / 0.6833 GB, free: 16.9 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.9731/1.597, allocations: 406.6 MB / 1.08 GB, free: 45.66 MB / 0.7292 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002393/1.597, allocations: 99.58 kB / 1.08 GB, free: 45.61 MB / 0.7292 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_LowTemperature Notification: Performance of FrontEnd: time 0.2327/1.83, allocations: 81.99 MB / 1.161 GB, free: 5.699 MB / 0.7605 GB