Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.008916/0.008916, allocations: 111.4 kB / 15.06 MB, free: 5.965 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001112/0.001112, allocations: 182.8 kB / 15.94 MB, free: 5.93 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 1.906/1.906, allocations: 194.5 MB / 211.3 MB, free: 11.05 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.123/2.123, allocations: 236.2 MB / 492.6 MB, free: 11.38 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004673/0.0004672, allocations: 12 kB / 0.5869 GB, free: 2.156 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5393/0.5397, allocations: 98.7 MB / 0.6833 GB, free: 16.72 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.066/1.606, allocations: 497.5 MB / 1.169 GB, free: 4.465 MB / 0.7761 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002928/1.606, allocations: 110.5 kB / 1.169 GB, free: 4.402 MB / 0.7761 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Geothermal/Borefields/Validation/ConstantHeatInjection_100Boreholes.mo:11:40-12:14:writable] Error: Component borHol.borFieDat of variability PARAM has binding borFieDat of higher variability VAR. Error: Error occurred while flattening model Buildings.Fluid.Geothermal.Borefields.Validation.ConstantHeatInjection_100Boreholes Notification: Performance of FrontEnd: time 0.1929/1.799, allocations: 56.04 MB / 1.224 GB, free: 5.164 MB / 0.823 GB