Running: ./testmodel.py --libraries=/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/./OMCompiler/build/lib/omlibrary/ --ompython_omhome=/usr Buildings_6.0.0_Buildings.Examples.VAVReheat.Guideline36.conf.json Using package Buildings with version 6.0.0 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo) Using package Modelica with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo) Using package Complex with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo) Using package ModelicaServices with version 3.2.2 (/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo) Running command: translateModel(Buildings.Examples.VAVReheat.Guideline36,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_6.0.0_Buildings.Examples.VAVReheat.Guideline36") Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/ModelicaServices 3.2.2/package.mo): time 0.01561/0.01561, allocations: 111 kB / 15.05 MB, free: 5.941 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Complex 3.2.2.mo): time 0.001148/0.001148, allocations: 183.7 kB / 15.95 MB, free: 5.895 MB / 13.93 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Modelica 3.2.2/package.mo): time 1.925/1.925, allocations: 194.5 MB / 211.3 MB, free: 11.23 MB / 170.7 MB Notification: Performance of loadFile(/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/package.mo): time 2.198/2.198, allocations: 236.2 MB / 492.6 MB, free: 11.36 MB / 394.7 MB Notification: Performance of FrontEnd - loaded program: time 0.000471/0.0004712, allocations: 12 kB / 0.5869 GB, free: 2.164 MB / 490.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.5462/0.5467, allocations: 98.7 MB / 0.6833 GB, free: 16.69 MB / 0.5261 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.696/7.243, allocations: 2.752 GB / 3.436 GB, free: 3.938 MB / 0.823 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002194/7.243, allocations: 91.95 kB / 3.436 GB, free: 3.848 MB / 0.823 GB [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/Outside.mo:28:3-31:49:writable] Notification: From here: [/var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/lib/omlibrary/Buildings 6.0.0/Fluid/Sources/BaseClasses/PartialSource.mo:38:3-40:49:writable] Error: Duplicate elements (due to inherited elements) not identical: first element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg", final quantity = Medium.substanceNames) "Needed to connect to conditional connector" second element is: .Modelica.Blocks.Interfaces.RealInput[Medium.nX] X_in_internal(each final unit = "kg/kg") "Needed to connect to conditional connector" Error: Error occurred while flattening model Buildings.Examples.VAVReheat.Guideline36 Notification: Performance of FrontEnd: time 0.5902/7.834, allocations: 39.67 MB / 3.474 GB, free: 224.7 MB / 0.823 GB