Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_3.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Using package ModelicaServices with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Running command: translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL") translateModel(Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo): time 0.8424/0.8424, allocations: 133.7 MB / 148.6 MB, free: 13.61 MB / 122.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.001207/0.001207, allocations: 175.2 kB / 180.9 MB, free: 15.05 MB / 154.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.666/1.666, allocations: 170.7 MB / 383.7 MB, free: 16.25 MB / 282.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001748/0.001748, allocations: 114 kB / 454.6 MB, free: 9.848 MB / 346.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.1876/0.1881, allocations: 73.41 MB / 0.6812 GB, free: 5.543 MB / 474.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.136/1.324, allocations: 377.7 MB / 1.05 GB, free: 108.8 MB / 0.6042 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002667/1.324, allocations: 89.95 kB / 1.05 GB, free: 108.7 MB / 0.6042 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/Fluid/HeatPumps/Examples/Carnot_TCon.mo:17:3-31:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Buildings.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.HeatPumps.Validation.Carnot_TCon_etaPL Notification: Performance of FrontEnd: time 0.1454/1.47, allocations: 83.1 MB / 1.131 GB, free: 29.82 MB / 0.6042 GB