Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_1.6_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Using package Buildings with version 1.6 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo) Running command: translateModel(Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl") translateModel(Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo): time 0.5849/0.5849, allocations: 95.62 MB / 110.6 MB, free: 9.375 MB / 90.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.001754/0.001754, allocations: 165.9 kB / 134.2 MB, free: 2.258 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.753/1.753, allocations: 170.7 MB / 328.4 MB, free: 12.25 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001944/0.001944, allocations: 109.8 kB / 390.7 MB, free: 13.95 MB / 314.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0005211/0.0005211, allocations: 12 kB / 462.7 MB, free: 35.69 MB / 314.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1644/0.1649, allocations: 61.53 MB / 0.512 GB, free: 6.09 MB / 346.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 14.63/14.8, allocations: 5.619 GB / 6.131 GB, free: 162.5 MB / 0.5261 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003579/14.8, allocations: 96.38 kB / 6.131 GB, free: 162.5 MB / 0.5261 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/Fluid/Interfaces/FourPort.mo:6:15-8:45:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/Fluid/HeatExchangers/Examples/WetCoilCounterFlowPControl.mo:74:3-90:40:writable] Error: component hex contains the definition of a partial class Medium1. Please redeclare it to any package compatible with Modelica.Media.Interfaces.PartialMedium. Error: Error occurred while flattening model Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPControl Notification: Performance of FrontEnd: time 8.379/23.18, allocations: 1.897 GB / 8.028 GB, free: 45.09 MB / 0.6042 GB