Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_1.6_Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo) Using package Modelica with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo) Using package Complex with version 3.2.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo) Using package Buildings with version 1.6 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo) Running command: translateModel(Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable") translateModel(Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_1.6_Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/package.mo): time 0.5558/0.5558, allocations: 95.61 MB / 110.6 MB, free: 9.398 MB / 90.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.1+maint.om/package.mo): time 0.001239/0.001239, allocations: 164.2 kB / 134.2 MB, free: 2.266 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.1+maint.om/package.mo): time 1.502/1.502, allocations: 170.7 MB / 328.4 MB, free: 12.29 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.1+maint.om/package.mo): time 0.001972/0.001972, allocations: 99.41 kB / 390.7 MB, free: 13.95 MB / 314.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003621/0.0003621, allocations: 8 kB / 462.7 MB, free: 35.7 MB / 314.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1353/0.1356, allocations: 61.53 MB / 0.512 GB, free: 6.098 MB / 346.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.079/1.215, allocations: 418.1 MB / 0.9203 GB, free: 10.8 MB / 0.5261 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003164/1.215, allocations: 103.1 kB / 0.9204 GB, free: 10.74 MB / 0.5261 GB Error: Dimensions must be parameter or constant expression (in size(y, 1)). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 1.6.0+build.1/Fluid/Actuators/Valves/Examples/TwoWayValveTable.mo:32:5-32:31:writable] Error: Component valTab.flowCharacteristics of variability PARAM has binding datVal of higher variability VAR. Error: Error occurred while flattening model Buildings.Fluid.Actuators.Valves.Examples.TwoWayValveTable Notification: Performance of FrontEnd: time 0.4418/1.657, allocations: 88.32 MB / 1.007 GB, free: 142.2 MB / 0.5261 GB