Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: translateModel(BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=480,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater") translateModel(BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater,tolerance=1e-06,outputFormat="empty",numberOfIntervals=480,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.7853/0.7853, allocations: 128.7 MB / 143.7 MB, free: 2.285 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001073/0.001073, allocations: 186.1 kB / 173.8 MB, free: 6.113 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.836/1.836, allocations: 205.4 MB / 409 MB, free: 10.47 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008417/0.0008419, allocations: 90.92 kB / 486.6 MB, free: 12.99 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003801/0.0003801, allocations: 12.16 kB / 0.5603 GB, free: 97.52 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2017/0.2021, allocations: 76.76 MB / 0.6353 GB, free: 30.57 MB / 442.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo:2:1-8495:13:writable] Error: Class Units.SI.Volume not found in scope Modelica. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/Systems/DHW/Electric/ResistiveWaterHeater.mo:4:3-5:38:writable] Error: Class Modelica.Units.SI.Volume not found in scope BuildSysPro.Systems.DHW.Electric.ResistiveWaterHeater. Error: Error occurred while flattening model BuildSysPro.Systems.DHW.Examples.DHWResistiveWaterHeater Notification: Performance of FrontEnd: time 0.1531/0.3553, allocations: 100.7 MB / 0.7336 GB, free: 9.754 MB / 0.5105 GB