Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package BuildSysPro with version 3.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo) Running command: translateModel(BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static") translateModel(BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/package.mo): time 0.7877/0.7877, allocations: 128.7 MB / 143.7 MB, free: 2.309 MB / 106.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001169/0.001169, allocations: 188.5 kB / 173.8 MB, free: 6.125 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.972/1.972, allocations: 205.4 MB / 409 MB, free: 10.49 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009293/0.0009294, allocations: 98.55 kB / 486.6 MB, free: 13 MB / 378.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003812/0.0003812, allocations: 13.84 kB / 0.5604 GB, free: 97.54 MB / 442.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1924/0.1928, allocations: 76.76 MB / 0.6353 GB, free: 30.56 MB / 442.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.322/1.515, allocations: 383.9 MB / 1.01 GB, free: 241.3 MB / 0.6511 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002842/1.515, allocations: 103 kB / 1.01 GB, free: 241.3 MB / 0.6511 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/IBPSA/Media/Refrigerants/R410A/specificIsobaricHeatCapacityVap_Tv.mo:42:3-42:35:writable] Error: Variable A not found in scope BuildSysPro.IBPSA.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.5.0/IBPSA/Media/Refrigerants/R410A/isentropicExponentVap_Tv.mo:20:3-22:7:writable] Error: Class BuildSysPro.IBPSA.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv not found in scope BuildSysPro.IBPSA.Fluid.HeatPumps.Compressors.ScrollCompressor$heaPum$com.ref.isentropicExponentVap_Tv (looking for a function or record). Error: Error occurred while flattening model BuildSysPro.IBPSA.Fluid.HeatPumps.Validation.ScrollWaterToWater_Static Notification: Performance of FrontEnd: time 0.2147/1.73, allocations: 120.2 MB / 1.128 GB, free: 124.3 MB / 0.6511 GB