Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Annex60_1.0.0_Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Using package Annex60 with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo) Running command: translateModel(Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow") translateModel(Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo): time 0.3035/0.3035, allocations: 55.02 MB / 69.96 MB, free: 8.672 MB / 58.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001155/0.001155, allocations: 186.7 kB / 83.98 MB, free: 10.86 MB / 74.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.606/1.606, allocations: 194.4 MB / 292.3 MB, free: 3.602 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001715/0.001715, allocations: 123.1 kB / 350.7 MB, free: 9.105 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 0.000462/0.0004628, allocations: 8 kB / 418.9 MB, free: 37.04 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1222/0.1227, allocations: 57.65 MB / 476.5 MB, free: 11.32 MB / 330.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.01/1.132, allocations: 361.1 MB / 0.818 GB, free: 68.54 MB / 0.4948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002343/1.133, allocations: 90.14 kB / 0.818 GB, free: 68.49 MB / 0.4948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/HeatPumps/Validation/Carnot_TCon_reverseFlow.mo:33:3-47:71:writable] Error: Variable heaPum: Cyclically dependent constants or parameters found in scope Annex60.Fluid.HeatPumps.Carnot_TCon$heaPum: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Annex60.Fluid.HeatPumps.Validation.Carnot_TCon_reverseFlow Notification: Performance of FrontEnd: time 0.4872/1.62, allocations: 103 MB / 0.9187 GB, free: 148.2 MB / 0.4948 GB