Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Using package Annex60 with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo) Running command: translateModel(Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow") translateModel(Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo): time 0.3868/0.3868, allocations: 55.01 MB / 69.96 MB, free: 8.668 MB / 58.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001164/0.001164, allocations: 188 kB / 83.98 MB, free: 10.85 MB / 74.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.629/1.629, allocations: 194.4 MB / 292.3 MB, free: 3.602 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.002204/0.002204, allocations: 112.7 kB / 350.7 MB, free: 9.102 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0005325/0.0005325, allocations: 12 kB / 418.9 MB, free: 37.03 MB / 298.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1533/0.1538, allocations: 57.65 MB / 476.5 MB, free: 11.31 MB / 330.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 1.101/1.255, allocations: 361.1 MB / 0.818 GB, free: 68.64 MB / 0.4948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004592/1.255, allocations: 96.67 kB / 0.8181 GB, free: 68.59 MB / 0.4948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/Chillers/Validation/Carnot_TEva_reverseFlow.mo:22:3-37:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Annex60.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow Notification: Performance of FrontEnd: time 0.4981/1.753, allocations: 81.46 MB / 0.8976 GB, free: 144 MB / 0.4948 GB