Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_cpp_PowerSystems.Examples.AC3ph.Transmission.DoubleLineTG.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo", uses=false) Using package PowerSystems with version 1.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerSystems.Examples.AC3ph.Transmission.DoubleLineTG,fileNamePrefix="PowerSystems_cpp_PowerSystems_Examples_AC3ph_Transmission_DoubleLineTG",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerSystems.Examples.AC3ph.Transmission.DoubleLineTG,fileNamePrefix="PowerSystems_cpp_PowerSystems_Examples_AC3ph_Transmission_DoubleLineTG",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001603/0.001602, allocations: 182 kB / 15.76 MB, free: 6.344 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.114/2.114, allocations: 205.4 MB / 221.9 MB, free: 13.83 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001138/0.001138, allocations: 98.86 kB / 270.2 MB, free: 13.36 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo): time 0.3059/0.3059, allocations: 38.06 MB / 356.6 MB, free: 0.8125 MB / 250.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004791/0.0004789, allocations: 16 kB / 422.8 MB, free: 26.34 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1198/0.1203, allocations: 56.34 MB / 479.1 MB, free: 1.957 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.6104/0.7308, allocations: 162.8 MB / 0.6269 GB, free: 1.988 MB / 426.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003619/0.7312, allocations: 101 kB / 0.627 GB, free: 1.934 MB / 426.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Transmission.DoubleLineTG Notification: Performance of FrontEnd: time 0.2201/0.9513, allocations: 46.11 MB / 0.672 GB, free: 9.855 MB / 474.7 MB