Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_cpp_PowerSystems.Examples.AC3ph.Generation.Islanding.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo", uses=false) Using package PowerSystems with version 1.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerSystems.Examples.AC3ph.Generation.Islanding,fileNamePrefix="PowerSystems_cpp_PowerSystems_Examples_AC3ph_Generation_Islanding",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerSystems.Examples.AC3ph.Generation.Islanding,fileNamePrefix="PowerSystems_cpp_PowerSystems_Examples_AC3ph_Generation_Islanding",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001641/0.001641, allocations: 184 kB / 15.76 MB, free: 6.363 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.11/2.11, allocations: 205.4 MB / 221.9 MB, free: 13.84 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001201/0.001201, allocations: 94.86 kB / 270.2 MB, free: 13.36 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/package.mo): time 0.294/0.294, allocations: 38.07 MB / 356.6 MB, free: 0.8008 MB / 250.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0005121/0.0005122, allocations: 19.98 kB / 422.8 MB, free: 26.33 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1259/0.1264, allocations: 56.32 MB / 479.1 MB, free: 1.949 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.5962/0.7227, allocations: 137.5 MB / 0.6022 GB, free: 10.51 MB / 410.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003826/0.7232, allocations: 101.3 kB / 0.6023 GB, free: 10.46 MB / 410.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.1-master/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Generation.Islanding Notification: Performance of FrontEnd: time 0.213/0.9362, allocations: 42.68 MB / 0.644 GB, free: 5.262 MB / 442.7 MB