Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_PowerSystems.Examples.Wind.WindTurbine_PSGI.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo", uses=false) Using package PowerSystems with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerSystems.Examples.Wind.WindTurbine_PSGI,fileNamePrefix="PowerSystems_PowerSystems_Examples_Wind_WindTurbine_PSGI",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerSystems.Examples.Wind.WindTurbine_PSGI,fileNamePrefix="PowerSystems_PowerSystems_Examples_Wind_WindTurbine_PSGI",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001056/0.001056, allocations: 178.9 kB / 16.38 MB, free: 5.766 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.2/1.2, allocations: 194.5 MB / 211.6 MB, free: 3.051 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001606/0.001606, allocations: 127.1 kB / 256.9 MB, free: 4.348 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo): time 0.1601/0.1601, allocations: 38.01 MB / 340.1 MB, free: 1.355 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004333/0.0004332, allocations: 15.98 kB / 403.9 MB, free: 68.7 MB / 314.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.09505/0.0955, allocations: 53.23 MB / 457.1 MB, free: 15.47 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.4095/0.5051, allocations: 140.5 MB / 0.5836 GB, free: 3.902 MB / 394.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002627/0.5054, allocations: 92.33 kB / 0.5837 GB, free: 3.855 MB / 394.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:424:36-424:44:writable] Warning: Non-array modification '"1"' for array component, possibly due to missing 'each'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:430:36-430:44:writable] Warning: Non-array modification '"1"' for array component, possibly due to missing 'each'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:2240:3-2240:48:writable] Error: Could not evaluate structural parameter (or constant): n_d which gives dimensions of array: L_rd[n_d]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.Wind.WindTurbine_PSGI Notification: Performance of FrontEnd: time 0.1002/0.6056, allocations: 35.92 MB / 0.6187 GB, free: 4.488 MB / 426.7 MB