Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerSystems_PowerSystems.Examples.AC3ph.Elementary.Machines.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo", uses=false) Using package PowerSystems with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo) Using package ModelicaServices with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo) Using package Modelica with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo) Using package Complex with version 3.2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerSystems.Examples.AC3ph.Elementary.Machines,fileNamePrefix="PowerSystems_PowerSystems_Examples_AC3ph_Elementary_Machines",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerSystems.Examples.AC3ph.Elementary.Machines,fileNamePrefix="PowerSystems_PowerSystems_Examples_AC3ph_Elementary_Machines",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.2+maint.om/package.mo): time 0.001131/0.001131, allocations: 179.8 kB / 16.38 MB, free: 5.762 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.2+maint.om/package.mo): time 1.263/1.263, allocations: 194.5 MB / 211.6 MB, free: 3.055 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.2+maint.om/package.mo): time 0.001612/0.001612, allocations: 110.4 kB / 256.9 MB, free: 4.34 MB / 202.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/package.mo): time 0.1623/0.1623, allocations: 38 MB / 340.1 MB, free: 1.355 MB / 282.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003672/0.0003673, allocations: 16 kB / 403.9 MB, free: 68.72 MB / 314.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.08075/0.08114, allocations: 53.23 MB / 457.1 MB, free: 15.47 MB / 314.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.2978/0.379, allocations: 109 MB / 0.5529 GB, free: 2.52 MB / 362.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003252/0.3794, allocations: 97.39 kB / 0.553 GB, free: 2.469 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerSystems 1.0.0/AC3ph/Machines.mo:2208:3-2208:47:writable] Error: Could not evaluate structural parameter (or constant): n_r which gives dimensions of array: L_r[n_r]. Array dimensions must be known at compile time. Error: Error occurred while flattening model PowerSystems.Examples.AC3ph.Elementary.Machines Notification: Performance of FrontEnd: time 0.08566/0.4651, allocations: 28.88 MB / 0.5812 GB, free: 9.453 MB / 394.7 MB