Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Examples.ENTSOE.SteadyState.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Ignoring simflag -noemit -homotopyOnFirstTry=() since it seems broken on HelloWorld Running command: "" <> buildModelFMU(PowerGrids.Examples.ENTSOE.SteadyState,fileNamePrefix="PowerGrids_PowerGrids_Examples_ENTSOE_SteadyState",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerGrids.Examples.ENTSOE.SteadyState,fileNamePrefix="PowerGrids_PowerGrids_Examples_ENTSOE_SteadyState",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.006447/0.006447, allocations: 172 kB / 15.11 MB, free: 5.98 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.344/1.344, allocations: 205.4 MB / 221.3 MB, free: 13.84 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007961/0.0007962, allocations: 98.84 kB / 269.6 MB, free: 13.36 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.05411/0.05411, allocations: 14.19 MB / 332 MB, free: 8.734 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0003383/0.0003382, allocations: 6.938 kB / 396.4 MB, free: 49.63 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.08191/0.08228, allocations: 51.14 MB / 447.5 MB, free: 4.043 MB / 282.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3409/0.4232, allocations: 102.3 MB / 0.537 GB, free: 26.09 MB / 362.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002219/0.4235, allocations: 79.67 kB / 0.5371 GB, free: 26.09 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$GEN$port. Error: Error occurred while flattening model PowerGrids.Examples.ENTSOE.SteadyState Notification: Performance of FrontEnd: time 0.01736/0.4409, allocations: 8.636 MB / 0.5455 GB, free: 25.11 MB / 362.7 MB