Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr PowerGrids_PowerGrids.Electrical.Test.TestTransformerFixedRatio.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo", uses=false) Using package PowerGrids with version 1.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Running command: "" <> buildModelFMU(PowerGrids.Electrical.Test.TestTransformerFixedRatio,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TestTransformerFixedRatio",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(PowerGrids.Electrical.Test.TestTransformerFixedRatio,fileNamePrefix="PowerGrids_PowerGrids_Electrical_Test_TestTransformerFixedRatio",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.004822/0.004822, allocations: 171.8 kB / 15.11 MB, free: 5.973 MB / 13.93 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.279/1.279, allocations: 205.4 MB / 221.3 MB, free: 13.81 MB / 186.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0007586/0.0007585, allocations: 86.88 kB / 269.6 MB, free: 13.34 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/package.mo): time 0.05273/0.05273, allocations: 14.19 MB / 332 MB, free: 8.719 MB / 234.7 MB Notification: Performance of FrontEnd - loaded program: time 0.000297/0.000297, allocations: 13.91 kB / 393.7 MB, free: 51.12 MB / 282.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.08438/0.08469, allocations: 51.12 MB / 444.9 MB, free: 6.68 MB / 282.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.1124/0.1971, allocations: 84.86 MB / 0.5173 GB, free: 1.703 MB / 362.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0001958/0.1973, allocations: 71.97 kB / 0.5174 GB, free: 1.633 MB / 362.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/PowerGrids 1.0.2-master/Electrical/BaseClasses/PortAC.mo:49:3-50:32:writable] Error: Variable S.re not found in scope PowerGrids.Electrical.BaseClasses.PortAC$infiniteBus$port. Error: Error occurred while flattening model PowerGrids.Electrical.Test.TestTransformerFixedRatio Notification: Performance of FrontEnd: time 0.2057/0.4031, allocations: 5.611 MB / 0.5229 GB, free: 83.03 MB / 362.7 MB