Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr OpenHydraulics_OpenHydraulics.Circuits.Regenerative.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/package.mo", uses=false) Using package OpenHydraulics with version 1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/package.mo) Using package ModelicaServices with version 1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo) Using package Modelica with version 3.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo) Using package Complex with version 1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo) Running command: "" <> buildModelFMU(OpenHydraulics.Circuits.Regenerative,fileNamePrefix="OpenHydraulics_OpenHydraulics_Circuits_Regenerative",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(OpenHydraulics.Circuits.Regenerative,fileNamePrefix="OpenHydraulics_OpenHydraulics_Circuits_Regenerative",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo): time 0.009916/0.009915, allocations: 144.1 kB / 15.09 MB, free: 5.934 MB / 13.93 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:570:14-570:31:writable] Warning: Treating .0158271919734802 as 0.0158271919734802. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:570:48-570:65:writable] Warning: Treating .0942738402188500 as 0.0942738402188500. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:571:13-571:29:writable] Warning: Treating .155071987336585 as 0.155071987336585. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:571:47-571:63:writable] Warning: Treating .188821573960182 as 0.188821573960182. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:9-572:25:writable] Warning: Treating .199773405226859 as 0.199773405226859. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:42-572:58:writable] Warning: Treating .224926465333340 as 0.224926465333340. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:75-572:91:writable] Warning: Treating .242611071901408 as 0.242611071901408. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8490:35-8490:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of nom...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8600:35-8600:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of nomi...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8738:35-8738:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of a pr...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8793:35-8793:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss with linear or quadra...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo): time 1.543/1.543, allocations: 150.7 MB / 166.5 MB, free: 6.07 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo): time 0.001741/0.001741, allocations: 86.47 kB / 201.8 MB, free: 2.719 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/package.mo): time 0.07521/0.07521, allocations: 11.85 MB / 248.8 MB, free: 0.5938 MB / 170.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0004273/0.0004274, allocations: 9.688 kB / 296.5 MB, free: 26.75 MB / 202.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.07907/0.07952, allocations: 37.15 MB / 333.7 MB, free: 5.891 MB / 218.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3644/0.444, allocations: 64.84 MB / 398.5 MB, free: 20.75 MB / 266.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002859/0.4444, allocations: 73.64 kB / 398.6 MB, free: 20.75 MB / 266.7 MB Notification: Performance of FrontEnd - DAE generated: time 0.2542/0.6986, allocations: 72.15 MB / 470.7 MB, free: 9.727 MB / 298.7 MB Notification: Performance of FrontEnd: time 2.094e-06/0.6986, allocations: 0 / 470.7 MB, free: 9.727 MB / 298.7 MB Notification: Performance of Transformations before backend: time 0.0005262/0.6992, allocations: 79.92 kB / 470.8 MB, free: 9.648 MB / 298.7 MB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 612 * Number of variables: 612 Notification: Performance of Generate backend data structure: time 0.01308/0.7123, allocations: 3.403 MB / 474.2 MB, free: 6.109 MB / 298.7 MB Notification: Performance of prepare preOptimizeDAE: time 5.122e-05/0.7123, allocations: 12.03 kB / 474.2 MB, free: 6.098 MB / 298.7 MB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.001704/0.714, allocations: 341.5 kB / 474.6 MB, free: 5.754 MB / 298.7 MB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.002153/0.7162, allocations: 391.6 kB / 475 MB, free: 5.367 MB / 298.7 MB Notification: Performance of preOpt evaluateParameters (simulation): time 0.007913/0.7242, allocations: 2.046 MB / 477 MB, free: 3.246 MB / 298.7 MB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0005246/0.7247, allocations: 308.2 kB / 477.3 MB, free: 2.918 MB / 298.7 MB Notification: Performance of preOpt expandDerOperator (simulation): time 0.001278/0.726, allocations: 267.7 kB / 477.6 MB, free: 2.656 MB / 298.7 MB Notification: Performance of preOpt clockPartitioning (simulation): time 0.01125/0.7373, allocations: 2.868 MB / 480.4 MB, free: 15.72 MB / 314.7 MB Notification: Performance of preOpt findStateOrder (simulation): time 0.0001344/0.7375, allocations: 7.938 kB / 480.4 MB, free: 15.71 MB / 314.7 MB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0005925/0.7381, allocations: 99.98 kB / 480.5 MB, free: 15.62 MB / 314.7 MB Notification: Performance of preOpt inlineArrayEqn (simulation): time 7.346e-05/0.7382, allocations: 64 kB / 480.6 MB, free: 15.55 MB / 314.7 MB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.0102/0.7484, allocations: 2.603 MB / 483.2 MB, free: 12.94 MB / 314.7 MB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.04513/0.7936, allocations: 14.49 MB / 497.7 MB, free: 13 MB / 330.7 MB Notification: Performance of preOpt comSubExp (simulation): time 0.01278/0.8064, allocations: 3.061 MB / 0.489 GB, free: 9.816 MB / 330.7 MB Notification: Performance of preOpt evalFunc (simulation): time 0.0007418/0.8072, allocations: 151 kB / 0.4892 GB, free: 9.652 MB / 330.7 MB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.00758/0.8148, allocations: 1.446 MB / 0.4906 GB, free: 8.18 MB / 330.7 MB Notification: Performance of pre-optimization done (n=235): time 1.221e-05/0.8149, allocations: 4 kB / 0.4906 GB, free: 8.176 MB / 330.7 MB Notification: Performance of matching and sorting (n=261): time 0.06068/0.8756, allocations: 11.33 MB / 0.5016 GB, free: 12.49 MB / 346.7 MB Notification: Performance of inlineWhenForInitialization (initialization): time 0.000218/0.8759, allocations: 324.8 kB / 0.502 GB, free: 12.11 MB / 346.7 MB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.005345/0.8812, allocations: 2.037 MB / 0.5039 GB, free: 10.05 MB / 346.7 MB Notification: Performance of collectPreVariables (initialization): time 0.0007355/0.882, allocations: 81.7 kB / 0.504 GB, free: 9.969 MB / 346.7 MB Notification: Performance of collectInitialEqns (initialization): time 0.00177/0.8838, allocations: 1.195 MB / 0.5052 GB, free: 8.762 MB / 346.7 MB Notification: Performance of collectInitialBindings (initialization): time 0.001631/0.8855, allocations: 0.8663 MB / 0.506 GB, free: 7.883 MB / 346.7 MB Notification: Performance of simplifyInitialFunctions (initialization): time 0.0003124/0.8858, allocations: 48 kB / 0.5061 GB, free: 7.836 MB / 346.7 MB Notification: Performance of setup shared object (initialization): time 0.0002716/0.8861, allocations: 403 kB / 0.5065 GB, free: 7.438 MB / 346.7 MB Notification: Performance of preBalanceInitialSystem (initialization): time 0.003819/0.8899, allocations: 1.116 MB / 0.5076 GB, free: 6.316 MB / 346.7 MB Notification: Performance of partitionIndependentBlocks (initialization): time 0.004366/0.8943, allocations: 1.461 MB / 0.509 GB, free: 4.688 MB / 346.7 MB Notification: Performance of analyzeInitialSystem (initialization): time 0.004319/0.8987, allocations: 1.401 MB / 0.5103 GB, free: 3.203 MB / 346.7 MB Notification: Performance of solveInitialSystemEqSystem (initialization): time 2.422e-05/0.8988, allocations: 7.953 kB / 0.5104 GB, free: 3.195 MB / 346.7 MB Notification: Performance of matching and sorting (n=319) (initialization): time 0.2751/1.174, allocations: 3.529 MB / 0.5138 GB, free: 67.84 MB / 346.7 MB Notification: Performance of prepare postOptimizeDAE: time 0.0001414/1.174, allocations: 228.1 kB / 0.514 GB, free: 67.59 MB / 346.7 MB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 3.489e-05/1.174, allocations: 8.656 kB / 0.514 GB, free: 67.59 MB / 346.7 MB Notification: Performance of postOpt tearingSystem (initialization): time 0.0008926/1.175, allocations: 246.4 kB / 0.5143 GB, free: 67.55 MB / 346.7 MB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.004884/1.18, allocations: 0.5308 MB / 0.5148 GB, free: 67.55 MB / 346.7 MB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.007757/1.188, allocations: 6.554 MB / 0.5212 GB, free: 62.27 MB / 346.7 MB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.004525/1.192, allocations: 276.6 kB / 0.5214 GB, free: 62.27 MB / 346.7 MB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0008687/1.193, allocations: 116.6 kB / 0.5216 GB, free: 62.27 MB / 346.7 MB Warning: Assuming fixed start value for the following 10 variables: constantSpeed.phi:VARIABLE(unit = "rad" fixed = true ) "Angle of flange with respect to support (= flange.phi - support.phi)" type: Real constantDisplacementPump.portP.p:VARIABLE(flow=false min = max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, 2000.0)))))))))))))))))))))))))))))))))))))))))) max = min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, 1000000000.0)))))))))))))))))))))))))))))))))))))))))) start = constantDisplacementPump.fluidPower2MechRot.p_init unit = "Pa" fixed = true nominal = 100000.0 stateSelect=StateSelect.prefer ) "Pressure in the connection point" type: Real RegenValve.portB.p:VARIABLE(flow=false min = max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, 2000.0)))))))))))))))) max = min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, 1000000000.0)))))))))))))))) start = RegenValve.P2B.p_init unit = "Pa" fixed = true nominal = 100000.0 stateSelect=StateSelect.prefer ) "Pressure in the connection point" type: Real RegenValve.portA.p:VARIABLE(flow=false min = max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, 2000.0)))))))))))))))))))))))))))) max = min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, 1000000000.0)))))))))))))))))))))))))))) start = RegenValve.P2A.p_init unit = "Pa" fixed = true nominal = 100000.0 stateSelect=StateSelect.prefer ) "Pressure in the connection point" type: Real doubleActingCylinder.damper.v_rel:VARIABLE(start = 0.0 unit = "m/s" fixed = true stateSelect=StateSelect.prefer ) "Relative velocity (= der(s_rel))" type: Real doubleActingCylinder.cushionRod.flowFraction:VARIABLE(fixed = true protected = true ) "fraction of flow allowed by cushion" type: Real doubleActingCylinder.cushionRod.reliefValve.valvePosition:VARIABLE(start = 0.0 fixed = true ) "Normalized valve position (between 0 and 1)" type: Real doubleActingCylinder.cushionHead.flowFraction:VARIABLE(fixed = true protected = true ) "fraction of flow allowed by cushion" type: Real doubleActingCylinder.cushionHead.reliefValve.valvePosition:VARIABLE(start = 0.0 fixed = true ) "Normalized valve position (between 0 and 1)" type: Real reliefValve.valvePosition:VARIABLE(start = 0.0 fixed = true ) "Normalized valve position (between 0 and 1)" type: Real Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 39 * Number of states: 0 () * Number of discrete variables: 32 (constantDisplacementPump.mechanicalPumpLosses.free,RegenValve.A2T.data.zetaLaminarKnown,RegenValve.P2A.data.zetaLaminarKnown,RegenValve.P2B.data.zetaLaminarKnown,doubleActingCylinder.cushionRod.reliefValve.variableRestriction.data.zetaLaminarKnown,doubleActingCylinder.cushionRod.cushionRestriction.data.zetaLaminarKnown,doubleActingCylinder.cushionHead.reliefValve.variableRestriction.data.zetaLaminarKnown,doubleActingCylinder.cushionHead.cushionRestriction.data.zetaLaminarKnown,reliefValve.variableRestriction.data.zetaLaminarKnown,$whenCondition2,$whenCondition1,$whenCondition3,$whenCondition4,reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cylinderChamberHead.empty,doubleActingCylinder.cylinderChamberRod.empty,doubleActingCylinder.cushionHead.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.cushionTableBlock.tableID,doubleActingCylinder.cushionRod.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.cushionTableBlock.tableID,RegenValve.P2B.MeteringTable.tableID,RegenValve.P2A.MeteringTable.tableID,RegenValve.A2T.MeteringTable.tableID,$PRE.constantDisplacementPump.mechanicalPumpLosses.startForward,constantDisplacementPump.mechanicalPumpLosses.startForward,$PRE.constantDisplacementPump.mechanicalPumpLosses.startBackward,constantDisplacementPump.mechanicalPumpLosses.startBackward,constantDisplacementPump.mechanicalPumpLosses.locked,$PRE.constantDisplacementPump.mechanicalPumpLosses.mode,constantDisplacementPump.mechanicalPumpLosses.mode) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (302): * Single equations (assignments): 290 * Array equations: 0 * Algorithm blocks: 8 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 4 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 3 {(1,100.0%) 6,(1,100.0%) 5,(1,100.0%) 3} * Non-linear torn systems: 1 {1 3} Notification: Performance of prepare postOptimizeDAE: time 0.004059/1.197, allocations: 1.391 MB / 0.5229 GB, free: 61.83 MB / 346.7 MB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.001038/1.198, allocations: 301.3 kB / 0.5232 GB, free: 61.83 MB / 346.7 MB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.0129/1.211, allocations: 3.807 MB / 0.5269 GB, free: 61.18 MB / 346.7 MB Notification: Performance of postOpt inlineArrayEqn (simulation): time 4.178e-05/1.211, allocations: 30 kB / 0.5269 GB, free: 61.18 MB / 346.7 MB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.345e-05/1.211, allocations: 3.875 kB / 0.527 GB, free: 61.18 MB / 346.7 MB Notification: Performance of postOpt simplifysemiLinear (simulation): time 6.462e-05/1.211, allocations: 13.97 kB / 0.527 GB, free: 61.18 MB / 346.7 MB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.02346/1.235, allocations: 7.704 MB / 0.5345 GB, free: 59.8 MB / 346.7 MB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 2.468e-05/1.235, allocations: 8.562 kB / 0.5345 GB, free: 59.8 MB / 346.7 MB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.00433/1.239, allocations: 469.9 kB / 0.5349 GB, free: 59.8 MB / 346.7 MB Notification: Performance of postOpt tearingSystem (simulation): time 0.0007538/1.24, allocations: 204.3 kB / 0.5351 GB, free: 59.77 MB / 346.7 MB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0006915/1.241, allocations: 84.56 kB / 0.5352 GB, free: 59.77 MB / 346.7 MB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.006277/1.247, allocations: 6.123 MB / 0.5412 GB, free: 54.63 MB / 346.7 MB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 1.058e-05/1.247, allocations: 12.14 kB / 0.5412 GB, free: 54.63 MB / 346.7 MB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.01452/1.262, allocations: 5.678 MB / 0.5468 GB, free: 53.16 MB / 346.7 MB Notification: Performance of postOpt removeConstants (simulation): time 0.003069/1.265, allocations: 0.7007 MB / 0.5474 GB, free: 52.96 MB / 346.7 MB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.00121/1.266, allocations: 66.95 kB / 0.5475 GB, free: 52.96 MB / 346.7 MB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.003824/1.27, allocations: 207.2 kB / 0.5477 GB, free: 52.96 MB / 346.7 MB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.001174/1.271, allocations: 310.1 kB / 0.548 GB, free: 52.96 MB / 346.7 MB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0005145/1.272, allocations: 110.7 kB / 0.5481 GB, free: 52.96 MB / 346.7 MB Notification: Performance of sorting global known variables: time 0.004526/1.276, allocations: 1.594 MB / 0.5497 GB, free: 52.81 MB / 346.7 MB Notification: Performance of sort global known variables: time 1.022e-06/1.276, allocations: 0 / 0.5497 GB, free: 52.81 MB / 346.7 MB Notification: Performance of remove unused functions: time 0.00527/1.282, allocations: 0.8367 MB / 0.5505 GB, free: 52.81 MB / 346.7 MB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 21 * Number of states: 16 (reliefValve.valvePosition,doubleActingCylinder.cylinderChamberHead.port[3].p,doubleActingCylinder.cylinderChamberRod.port[3].p,doubleActingCylinder.cushionHead.reliefValve.valvePosition,doubleActingCylinder.cushionHead.flowFraction,doubleActingCylinder.cushionRod.reliefValve.valvePosition,doubleActingCylinder.cushionRod.flowFraction,doubleActingCylinder.damper.s_rel,doubleActingCylinder.damper.v_rel,circuitTank.volumeOpen.m,RegenValve.portA.p,RegenValve.portB.p,RegenValve.dynamicResponse.y,RegenValve.dynamicResponse.yd,constantDisplacementPump.portP.p,constantSpeed.phi) * Number of discrete variables: 20 ($whenCondition2,$whenCondition1,$whenCondition3,$whenCondition4,reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cylinderChamberHead.empty,doubleActingCylinder.cylinderChamberRod.empty,doubleActingCylinder.cushionHead.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.cushionTableBlock.tableID,doubleActingCylinder.cushionRod.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.cushionTableBlock.tableID,RegenValve.P2B.MeteringTable.tableID,RegenValve.P2A.MeteringTable.tableID,RegenValve.A2T.MeteringTable.tableID,constantDisplacementPump.mechanicalPumpLosses.startForward,constantDisplacementPump.mechanicalPumpLosses.startBackward,constantDisplacementPump.mechanicalPumpLosses.locked,constantDisplacementPump.mechanicalPumpLosses.mode) * Number of discrete states: 5 (constantDisplacementPump.mechanicalPumpLosses.mode,constantDisplacementPump.mechanicalPumpLosses.startBackward,constantDisplacementPump.mechanicalPumpLosses.startForward,$whenCondition3,$whenCondition4) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (271): * Single equations (assignments): 249 * Array equations: 0 * Algorithm blocks: 8 * Record equations: 0 * When equations: 10 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 4 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 3 {(1,100.0%) 5,(1,100.0%) 3,(1,100.0%) 2} * Non-linear torn systems: 1 {1 3} Notification: Performance of Backend phase and start with SimCode phase: time 0.01762/1.299, allocations: 7.898 MB / 0.5582 GB, free: 49.46 MB / 346.7 MB Notification: Performance of simCode: created initialization part: time 0.01247/1.312, allocations: 3.489 MB / 0.5616 GB, free: 48.44 MB / 346.7 MB Notification: Performance of simCode: created event and clocks part: time 1.744e-05/1.312, allocations: 0 / 0.5616 GB, free: 48.44 MB / 346.7 MB Notification: Performance of simCode: created simulation system equations: time 0.009339/1.321, allocations: 2.44 MB / 0.564 GB, free: 47.47 MB / 346.7 MB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01676/1.338, allocations: 1.175 MB / 0.5651 GB, free: 47.44 MB / 346.7 MB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFUnit.mo:883:7-883:68:writable] Error: Internal error function lexer failed Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.08182/1.42, allocations: 27.04 MB / 0.5915 GB, free: 31.57 MB / 346.7 MB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.00277/1.423, allocations: 2.025 MB / 0.5935 GB, free: 30.7 MB / 346.7 MB Notification: Performance of simCode: alias equations: time 0.004125/1.427, allocations: 0.5004 MB / 0.594 GB, free: 30.63 MB / 346.7 MB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.003598/1.431, allocations: 1.292 MB / 0.5953 GB, free: 29.65 MB / 346.7 MB Notification: Performance of SimCode: time 7.81e-07/1.431, allocations: 0 / 0.5953 GB, free: 29.65 MB / 346.7 MB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.4406/1.871, allocations: 77.42 MB / 0.6709 GB, free: 63.76 MB / 346.7 MB Notification: Performance of buildModelFMU: configured platform static using cached values: time 0.000296/1.872, allocations: 241.2 kB / 0.6711 GB, free: 63.51 MB / 346.7 MB Error: Error building simulator. Build log: clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative.c:7: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.h:3: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:1051:11: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_k1 == 0.0)) ~~~~^~~~~~ OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:1051:11: note: remove extraneous parentheses around the comparison to silence this warning if((_k1 == 0.0)) ~ ^ ~ OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:1051:11: note: use '=' to turn this equality comparison into an assignment if((_k1 == 0.0)) ^~ = 3 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_records.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_records.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_records.c:4: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_01exo.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_01exo.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_01exo.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_02nls.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_02nls.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_02nls.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_03lsy.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_03lsy.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_03lsy.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_04set.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_04set.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_04set.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_05evt.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_05evt.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_05evt.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_06inz.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_06inz.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_06inz.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_07dly.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_07dly.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_07dly.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_08bnd.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_08bnd.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_08bnd.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_09alg.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_09alg.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_09alg.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_10asr.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_10asr.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_10asr.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_11mix.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_11mix.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_11mix.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_12jac.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_12jac.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_12jac.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_13opt.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_13opt.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_13opt.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_14lnz.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_14lnz.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_14lnz.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_15syn.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_15syn.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_15syn.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_16dae.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_16dae.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_16dae.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_17inl.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_17inl.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_17inl.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_Regenerative_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_init_fmu.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_init_fmu.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_init_fmu.c:1: In file included from ./simulation_data.h:39: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_FMU.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_FMU.c In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_FMU.c:9: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ In file included from OpenHydraulics_OpenHydraulics_Circuits_Regenerative_FMU.c:55: ./fmi-export/fmu2_model_interface.c.inc:79:11: warning: enumeration value 'modelSlaveInitialized' not handled in switch [-Wswitch] switch (comp->state) ^ ./fmi-export/fmu2_model_interface.c.inc:168:16: warning: passing 'char **' to parameter of type 'const char **' discards qualifiers in nested pointer types [-Wincompatible-pointer-types-discards-qualifiers] GC_vasprintf(&str, msg, args); ^~~~ ./gc/../meta/../util/modelica_string.h:71:31: note: passing argument to parameter 'strp' here int GC_vasprintf(const char **strp, const char *fmt, va_list ap); ^ 4 warnings generated. mkdir -p ../binaries/linux64 clang -shared -o OpenHydraulics_OpenHydraulics_Circuits_Regenerative.so OpenHydraulics_OpenHydraulics_Circuits_Regenerative.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_records.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_01exo.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_02nls.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_03lsy.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_04set.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_05evt.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_06inz.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_07dly.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_08bnd.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_09alg.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_10asr.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_11mix.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_12jac.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_13opt.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_14lnz.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_15syn.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_16dae.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_17inl.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_init_fmu.o OpenHydraulics_OpenHydraulics_Circuits_Regenerative_FMU.o -L"/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/Circuits" -Wl,-Bstatic "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" "-L/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/x86_64-linux" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/x86_64-linux" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/linux64" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/linux64" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library" -lModelicaExternalC -Wl,-Bdynamic -L'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -Wl,-rpath,'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -lSimulationRuntimeFMI -Wl,--no-as-needed -Wl,--disable-new-dtags -llapack -lblas -lm -lpthread -rdynamic -Wl,--no-undefined /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libModelicaExternalC.a(ModelicaInternal.o): In function `ModelicaInternal_temporaryFileName': ModelicaInternal.c:(.text+0x697): warning: the use of `tmpnam' is dangerous, better use `mkstemp' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionHead_24cushionTableBlock_tableInit': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x41): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionHead_24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0xb1): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionHead_24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0xc6): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionRod_24cushionTableBlock_tableInit': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x142): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionRod_24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x1b2): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionRod_24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x1c7): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24RegenValve_24A2T_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x243): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24RegenValve_24A2T_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x2b3): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24RegenValve_24A2T_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x2c8): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24RegenValve_24P2A_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x344): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24RegenValve_24P2A_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x3b4): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24RegenValve_24P2A_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x3c9): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24RegenValve_24P2B_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x445): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24RegenValve_24P2B_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x4b5): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24RegenValve_24P2B_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x4ca): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24cushionRestriction_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x546): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24cushionRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x5b6): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24cushionRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x5cb): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24reliefValve_24variableRestriction_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x647): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x6b7): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x6cc): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24cushionRestriction_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x748): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24cushionRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x7b8): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24cushionRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x7cd): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24reliefValve_24variableRestriction_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x849): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x8b9): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x8ce): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24reliefValve_24variableRestriction_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x94a): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x9ba): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_Regenerative_functions.c:(.text+0x9cf): undefined reference to `ModelicaTables_CombiTable1D_interpolate' clang: error: linker command failed with exit code 1 (use -v to see invocation) Makefile:57: recipe for target 'nozip' failed make: *** [nozip] Error 1