Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr OpenHydraulics_OpenHydraulics.Circuits.OpenCenterForceVelocityControl.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/package.mo", uses=false) Using package OpenHydraulics with version 1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/package.mo) Using package ModelicaServices with version 1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo) Using package Modelica with version 3.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo) Using package Complex with version 1.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo) Running command: "" <> buildModelFMU(OpenHydraulics.Circuits.OpenCenterForceVelocityControl,fileNamePrefix="OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(OpenHydraulics.Circuits.OpenCenterForceVelocityControl,fileNamePrefix="OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 1.1.0/package.mo): time 0.01499/0.01499, allocations: 145.5 kB / 15.09 MB, free: 5.934 MB / 13.93 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:570:14-570:31:writable] Warning: Treating .0158271919734802 as 0.0158271919734802. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:570:48-570:65:writable] Warning: Treating .0942738402188500 as 0.0942738402188500. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:571:13-571:29:writable] Warning: Treating .155071987336585 as 0.155071987336585. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:571:47-571:63:writable] Warning: Treating .188821573960182 as 0.188821573960182. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:9-572:25:writable] Warning: Treating .199773405226859 as 0.199773405226859. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:42-572:58:writable] Warning: Treating .224926465333340 as 0.224926465333340. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Math/Nonlinear.mo:572:75-572:91:writable] Warning: Treating .242611071901408 as 0.242611071901408. This is not standard Modelica and only done for compatibility with old code. Support for this feature may be removed in the future. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8490:35-8490:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of nom...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8600:35-8600:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of nomi...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8738:35-8738:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss in dependence of a pr...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Fluid/Dissipation.mo:8793:35-8793:107:writable] Warning: The file was not encoded in UTF-8: "

Calculation of a generic pressure loss with linear or quadra...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/package.mo): time 1.539/1.539, allocations: 150.7 MB / 166.5 MB, free: 6 MB / 138.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 1.1.0/package.mo): time 0.001733/0.001733, allocations: 78.59 kB / 201.8 MB, free: 2.66 MB / 170.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/package.mo): time 0.07595/0.07595, allocations: 11.85 MB / 248.8 MB, free: 0.5781 MB / 170.7 MB Notification: Performance of FrontEnd - loaded program: time 0.0006592/0.0006593, allocations: 8.516 kB / 296.5 MB, free: 26.7 MB / 202.7 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.08091/0.08163, allocations: 37.14 MB / 333.7 MB, free: 5.906 MB / 218.7 MB Notification: Performance of FrontEnd - scodeFlatten: time 0.3645/0.4462, allocations: 69.73 MB / 403.4 MB, free: 20.34 MB / 266.7 MB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002297/0.4464, allocations: 78.64 kB / 403.5 MB, free: 20.34 MB / 266.7 MB Notification: Performance of FrontEnd - DAE generated: time 0.3079/0.7544, allocations: 87.6 MB / 491.1 MB, free: 5.281 MB / 314.7 MB Notification: Performance of FrontEnd: time 2.365e-06/0.7545, allocations: 0 / 491.1 MB, free: 5.281 MB / 314.7 MB Notification: Performance of Transformations before backend: time 0.0006623/0.7551, allocations: 95.86 kB / 491.2 MB, free: 5.188 MB / 314.7 MB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 704 * Number of variables: 704 Notification: Performance of Generate backend data structure: time 0.01601/0.7712, allocations: 4.039 MB / 495.2 MB, free: 0.9883 MB / 314.7 MB Notification: Performance of prepare preOptimizeDAE: time 5.2e-05/0.7712, allocations: 12.03 kB / 495.2 MB, free: 0.9766 MB / 314.7 MB Notification: Performance of preOpt introduceOutputAliases (simulation): time 0.002268/0.7735, allocations: 388 kB / 495.6 MB, free: 0.5898 MB / 314.7 MB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.003287/0.7769, allocations: 474.6 kB / 496.1 MB, free: 124 kB / 314.7 MB Notification: Performance of preOpt evaluateParameters (simulation): time 0.01042/0.7873, allocations: 2.477 MB / 498.5 MB, free: 13.57 MB / 330.7 MB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0006/0.788, allocations: 332.5 kB / 498.9 MB, free: 13.22 MB / 330.7 MB Notification: Performance of preOpt expandDerOperator (simulation): time 0.001519/0.7895, allocations: 287.9 kB / 499.2 MB, free: 12.94 MB / 330.7 MB Notification: Performance of preOpt clockPartitioning (simulation): time 0.0132/0.8027, allocations: 3.518 MB / 0.4909 GB, free: 9.363 MB / 330.7 MB Notification: Performance of preOpt findStateOrder (simulation): time 0.0001426/0.8029, allocations: 3.938 kB / 0.4909 GB, free: 9.359 MB / 330.7 MB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0006724/0.8036, allocations: 120 kB / 0.491 GB, free: 9.242 MB / 330.7 MB Notification: Performance of preOpt inlineArrayEqn (simulation): time 7.923e-05/0.8037, allocations: 68 kB / 0.4911 GB, free: 9.176 MB / 330.7 MB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.01205/0.8158, allocations: 3.172 MB / 0.4942 GB, free: 5.992 MB / 330.7 MB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.03983/0.8557, allocations: 16.75 MB / 0.5105 GB, free: 3.625 MB / 346.7 MB Notification: Performance of preOpt comSubExp (simulation): time 0.2703/1.126, allocations: 3.585 MB / 0.514 GB, free: 56.47 MB / 346.7 MB Notification: Performance of preOpt evalFunc (simulation): time 0.0005915/1.127, allocations: 148.3 kB / 0.5142 GB, free: 56.38 MB / 346.7 MB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.006669/1.133, allocations: 1.793 MB / 0.5159 GB, free: 56.19 MB / 346.7 MB Notification: Performance of pre-optimization done (n=259): time 1.109e-05/1.134, allocations: 1.219 kB / 0.5159 GB, free: 56.19 MB / 346.7 MB Notification: Performance of matching and sorting (n=283): time 0.05655/1.19, allocations: 13.93 MB / 0.5295 GB, free: 53.21 MB / 346.7 MB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0001636/1.19, allocations: 382.6 kB / 0.5299 GB, free: 52.8 MB / 346.7 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Blocks/Continuous.mo:860:5-860:57:writable] Warning: Parameter fVController.PID.yMax has no value, and is fixed during initialization (fixed=true), using available start value (start=1.0) as default value. Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.007493/1.198, allocations: 2.591 MB / 0.5324 GB, free: 52.57 MB / 346.7 MB Notification: Performance of collectPreVariables (initialization): time 0.0009167/1.199, allocations: 81.7 kB / 0.5325 GB, free: 52.54 MB / 346.7 MB Notification: Performance of collectInitialEqns (initialization): time 0.002262/1.201, allocations: 1.501 MB / 0.534 GB, free: 52.23 MB / 346.7 MB Notification: Performance of collectInitialBindings (initialization): time 0.001872/1.203, allocations: 0.9358 MB / 0.5349 GB, free: 51.75 MB / 346.7 MB Notification: Performance of simplifyInitialFunctions (initialization): time 0.0006144/1.204, allocations: 58.36 kB / 0.5349 GB, free: 51.75 MB / 346.7 MB Notification: Performance of setup shared object (initialization): time 0.0002783/1.204, allocations: 409.1 kB / 0.5353 GB, free: 51.44 MB / 346.7 MB Notification: Performance of preBalanceInitialSystem (initialization): time 0.004763/1.209, allocations: 1.422 MB / 0.5367 GB, free: 51.43 MB / 346.7 MB Notification: Performance of partitionIndependentBlocks (initialization): time 0.00522/1.214, allocations: 1.827 MB / 0.5385 GB, free: 50.92 MB / 346.7 MB Notification: Performance of analyzeInitialSystem (initialization): time 0.005234/1.219, allocations: 1.71 MB / 0.5402 GB, free: 50.61 MB / 346.7 MB Notification: Performance of solveInitialSystemEqSystem (initialization): time 2.342e-05/1.219, allocations: 6.406 kB / 0.5402 GB, free: 50.61 MB / 346.7 MB Notification: Performance of matching and sorting (n=348) (initialization): time 0.01367/1.233, allocations: 4.329 MB / 0.5444 GB, free: 49.74 MB / 346.7 MB Notification: Performance of prepare postOptimizeDAE: time 0.0001232/1.233, allocations: 223.3 kB / 0.5446 GB, free: 49.49 MB / 346.7 MB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 3.212e-05/1.233, allocations: 9.625 kB / 0.5446 GB, free: 49.49 MB / 346.7 MB Notification: Performance of postOpt tearingSystem (initialization): time 0.0007332/1.234, allocations: 240 kB / 0.5448 GB, free: 49.45 MB / 346.7 MB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.005147/1.239, allocations: 0.6065 MB / 0.5454 GB, free: 49.45 MB / 346.7 MB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.006637/1.246, allocations: 6.491 MB / 0.5518 GB, free: 44.12 MB / 346.7 MB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.004912/1.251, allocations: 310 kB / 0.5521 GB, free: 44.12 MB / 346.7 MB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0009728/1.252, allocations: 145.7 kB / 0.5522 GB, free: 44.12 MB / 346.7 MB Warning: Assuming fixed start value for the following 7 variables: constantSpeed.phi:VARIABLE(unit = "rad" fixed = true ) "Angle of flange with respect to support (= flange.phi - support.phi)" type: Real constantDisplacementPump.portP.p:VARIABLE(flow=false min = max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, max(2000.0, 2000.0)))))))))))))))))))))))))))))))))))))))))) max = min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, min(1000000000.0, 1000000000.0)))))))))))))))))))))))))))))))))))))))))) start = constantDisplacementPump.fluidPower2MechRot.p_init unit = "Pa" fixed = true nominal = 100000.0 stateSelect=StateSelect.prefer ) "Pressure in the connection point" type: Real doubleActingCylinder.cushionRod.flowFraction:VARIABLE(fixed = true protected = true ) "fraction of flow allowed by cushion" type: Real doubleActingCylinder.cushionRod.reliefValve.valvePosition:VARIABLE(start = 0.0 fixed = true ) "Normalized valve position (between 0 and 1)" type: Real doubleActingCylinder.cushionHead.flowFraction:VARIABLE(fixed = true protected = true ) "fraction of flow allowed by cushion" type: Real doubleActingCylinder.cushionHead.reliefValve.valvePosition:VARIABLE(start = 0.0 fixed = true ) "Normalized valve position (between 0 and 1)" type: Real reliefValve.valvePosition:VARIABLE(start = 0.0 fixed = true ) "Normalized valve position (between 0 and 1)" type: Real Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 45 * Number of states: 0 () * Number of discrete variables: 36 (constantDisplacementPump.mechanicalPumpLosses.free,valve4_3posOCtandem.A2T.data.zetaLaminarKnown,valve4_3posOCtandem.P2B.data.zetaLaminarKnown,valve4_3posOCtandem.B2T.data.zetaLaminarKnown,valve4_3posOCtandem.P2A.data.zetaLaminarKnown,doubleActingCylinder.cushionRod.reliefValve.variableRestriction.data.zetaLaminarKnown,doubleActingCylinder.cushionRod.cushionRestriction.data.zetaLaminarKnown,doubleActingCylinder.cushionHead.reliefValve.variableRestriction.data.zetaLaminarKnown,doubleActingCylinder.cushionHead.cushionRestriction.data.zetaLaminarKnown,reliefValve.variableRestriction.data.zetaLaminarKnown,$whenCondition2,$whenCondition1,$whenCondition3,$whenCondition4,reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cylinderChamberHead.empty,doubleActingCylinder.cylinderChamberRod.empty,doubleActingCylinder.cushionHead.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.cushionTableBlock.tableID,doubleActingCylinder.cushionRod.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.cushionTableBlock.tableID,valve4_3posOCtandem.P2A.MeteringTable.tableID,valve4_3posOCtandem.B2T.MeteringTable.tableID,valve4_3posOCtandem.P2B.MeteringTable.tableID,valve4_3posOCtandem.A2T.MeteringTable.tableID,$PRE.constantDisplacementPump.mechanicalPumpLosses.startForward,constantDisplacementPump.mechanicalPumpLosses.startForward,$PRE.constantDisplacementPump.mechanicalPumpLosses.startBackward,constantDisplacementPump.mechanicalPumpLosses.startBackward,constantDisplacementPump.mechanicalPumpLosses.locked,$PRE.constantDisplacementPump.mechanicalPumpLosses.mode,constantDisplacementPump.mechanicalPumpLosses.mode,fVController.ForceProfile.tableID,fVController.VelocityProfile.tableID) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (334): * Single equations (assignments): 322 * Array equations: 0 * Algorithm blocks: 8 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 4 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 3 {(1,100.0%) 5,(1,100.0%) 3,(1,100.0%) 3} * Non-linear torn systems: 1 {1 3} Notification: Performance of prepare postOptimizeDAE: time 0.004405/1.256, allocations: 1.383 MB / 0.5536 GB, free: 43.71 MB / 346.7 MB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.00143/1.258, allocations: 361.2 kB / 0.5539 GB, free: 43.54 MB / 346.7 MB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.01592/1.274, allocations: 4.824 MB / 0.5586 GB, free: 42.77 MB / 346.7 MB Notification: Performance of postOpt inlineArrayEqn (simulation): time 3.321e-05/1.274, allocations: 31.28 kB / 0.5586 GB, free: 42.77 MB / 346.7 MB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.911e-05/1.274, allocations: 7.891 kB / 0.5587 GB, free: 42.76 MB / 346.7 MB Notification: Performance of postOpt simplifysemiLinear (simulation): time 8.658e-05/1.274, allocations: 14.3 kB / 0.5587 GB, free: 42.76 MB / 346.7 MB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.02896/1.303, allocations: 9.482 MB / 0.5679 GB, free: 40.99 MB / 346.7 MB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 2.551e-05/1.303, allocations: 7.625 kB / 0.5679 GB, free: 40.99 MB / 346.7 MB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.00484/1.308, allocations: 0.5003 MB / 0.5684 GB, free: 40.99 MB / 346.7 MB Notification: Performance of postOpt tearingSystem (simulation): time 0.0007304/1.309, allocations: 217.8 kB / 0.5686 GB, free: 40.96 MB / 346.7 MB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.0009387/1.309, allocations: 94.81 kB / 0.5687 GB, free: 40.96 MB / 346.7 MB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.006759/1.316, allocations: 6.354 MB / 0.5749 GB, free: 35.71 MB / 346.7 MB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 9.177e-06/1.316, allocations: 9.875 kB / 0.5749 GB, free: 35.71 MB / 346.7 MB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.02033/1.337, allocations: 7.24 MB / 0.582 GB, free: 33.07 MB / 346.7 MB Notification: Performance of postOpt removeConstants (simulation): time 0.003372/1.34, allocations: 0.8438 MB / 0.5828 GB, free: 32.54 MB / 346.7 MB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.001541/1.342, allocations: 81.41 kB / 0.5829 GB, free: 32.49 MB / 346.7 MB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.004533/1.346, allocations: 230.7 kB / 0.5831 GB, free: 32.45 MB / 346.7 MB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.001267/1.348, allocations: 325.3 kB / 0.5834 GB, free: 32.4 MB / 346.7 MB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.0007417/1.348, allocations: 144.7 kB / 0.5836 GB, free: 32.37 MB / 346.7 MB Notification: Performance of sorting global known variables: time 0.00561/1.354, allocations: 2.028 MB / 0.5856 GB, free: 31.65 MB / 346.7 MB Notification: Performance of sort global known variables: time 1.824e-06/1.354, allocations: 0 / 0.5856 GB, free: 31.65 MB / 346.7 MB Notification: Performance of remove unused functions: time 0.005938/1.36, allocations: 0.9415 MB / 0.5865 GB, free: 31.54 MB / 346.7 MB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 22 * Number of states: 16 (reliefValve.valvePosition,doubleActingCylinder.port_a.p,doubleActingCylinder.port_b.p,doubleActingCylinder.cylinderChamberHead.port[3].p,doubleActingCylinder.cylinderChamberRod.port[3].p,doubleActingCylinder.cushionHead.reliefValve.valvePosition,doubleActingCylinder.cushionHead.flowFraction,doubleActingCylinder.cushionRod.reliefValve.valvePosition,doubleActingCylinder.cushionRod.flowFraction,doubleActingCylinder.damper.s_rel,doubleActingCylinder.damper.v_rel,circuitTank.volumeOpen.m,valve4_3posOCtandem.dynamicResponse.y,valve4_3posOCtandem.dynamicResponse.yd,constantDisplacementPump.portP.p,constantSpeed.phi) * Number of discrete variables: 23 ($whenCondition2,$whenCondition1,$whenCondition3,$whenCondition4,reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cylinderChamberHead.empty,doubleActingCylinder.cylinderChamberRod.empty,doubleActingCylinder.cushionHead.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionHead.cushionTableBlock.tableID,doubleActingCylinder.cushionRod.cushionRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.reliefValve.variableRestriction.MeteringTable.tableID,doubleActingCylinder.cushionRod.cushionTableBlock.tableID,valve4_3posOCtandem.P2A.MeteringTable.tableID,valve4_3posOCtandem.B2T.MeteringTable.tableID,valve4_3posOCtandem.P2B.MeteringTable.tableID,valve4_3posOCtandem.A2T.MeteringTable.tableID,constantDisplacementPump.mechanicalPumpLosses.startForward,constantDisplacementPump.mechanicalPumpLosses.startBackward,constantDisplacementPump.mechanicalPumpLosses.locked,constantDisplacementPump.mechanicalPumpLosses.mode,fVController.ForceProfile.tableID,fVController.VelocityProfile.tableID) * Number of discrete states: 5 (constantDisplacementPump.mechanicalPumpLosses.mode,constantDisplacementPump.mechanicalPumpLosses.startBackward,constantDisplacementPump.mechanicalPumpLosses.startForward,$whenCondition3,$whenCondition4) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (296): * Single equations (assignments): 271 * Array equations: 0 * Algorithm blocks: 8 * Record equations: 0 * When equations: 13 * If-equations: 0 * Equation systems (linear and non-linear blocks): 0 * Torn equation systems: 4 * Mixed (continuous/discrete) equation systems: 0 Notification: Torn system details for strict tearing set: * Linear torn systems: 3 {(1,100.0%) 5,(1,100.0%) 3,(1,100.0%) 3} * Non-linear torn systems: 1 {1 3} Notification: Performance of Backend phase and start with SimCode phase: time 0.02043/1.38, allocations: 9.216 MB / 0.5955 GB, free: 25.97 MB / 346.7 MB Notification: Performance of simCode: created initialization part: time 0.01116/1.392, allocations: 3.968 MB / 0.5994 GB, free: 22.68 MB / 346.7 MB Notification: Performance of simCode: created event and clocks part: time 1.233e-05/1.392, allocations: 0 / 0.5994 GB, free: 22.68 MB / 346.7 MB Notification: Performance of simCode: created simulation system equations: time 0.006582/1.398, allocations: 2.72 MB / 0.602 GB, free: 20 MB / 346.7 MB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.01234/1.411, allocations: 1.372 MB / 0.6034 GB, free: 19.04 MB / 346.7 MB [/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/Compiler/NFFrontEnd/NFUnit.mo:883:7-883:68:writable] Error: Internal error function lexer failed Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.02932/1.44, allocations: 17.5 MB / 0.6204 GB, free: 2.441 MB / 346.7 MB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.003194/1.443, allocations: 2.331 MB / 0.6227 GB, free: 0.6445 MB / 346.7 MB Notification: Performance of simCode: alias equations: time 0.004539/1.448, allocations: 0.5742 MB / 0.6233 GB, free: 232 kB / 346.7 MB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.009896/1.458, allocations: 1.893 MB / 0.6251 GB, free: 15.91 MB / 362.7 MB Notification: Performance of SimCode: time 1.333e-06/1.458, allocations: 3.938 kB / 0.6251 GB, free: 15.9 MB / 362.7 MB Notification: Performance of buildModelFMU: Generate the FMI files: time 0.509/1.967, allocations: 88.9 MB / 0.7119 GB, free: 60.68 MB / 362.7 MB Notification: Performance of buildModelFMU: configured platform static using cached values: time 0.0003068/1.967, allocations: 248.6 kB / 0.7122 GB, free: 60.36 MB / 362.7 MB Error: Error building simulator. Build log: clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl.c:7: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.h:3: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:1238:11: warning: equality comparison with extraneous parentheses [-Wparentheses-equality] if((_k1 == 0.0)) ~~~~^~~~~~ OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:1238:11: note: remove extraneous parentheses around the comparison to silence this warning if((_k1 == 0.0)) ~ ^ ~ OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:1238:11: note: use '=' to turn this equality comparison into an assignment if((_k1 == 0.0)) ^~ = 3 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_records.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_records.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_records.c:4: In file included from ./meta/meta_modelica.h:49: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_01exo.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_01exo.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_01exo.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_02nls.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_02nls.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_02nls.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_03lsy.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_03lsy.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_03lsy.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_04set.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_04set.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_04set.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_05evt.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_05evt.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_05evt.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_06inz.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_06inz.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_06inz.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_07dly.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_07dly.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_07dly.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_08bnd.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_08bnd.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_08bnd.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_09alg.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_09alg.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_09alg.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_10asr.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_10asr.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_10asr.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_11mix.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_11mix.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_11mix.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_12jac.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_12jac.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_12jac.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_13opt.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_13opt.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_13opt.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_14lnz.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_14lnz.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_14lnz.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_15syn.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_15syn.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_15syn.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_16dae.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_16dae.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_16dae.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_17inl.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_17inl.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_17inl.c:2: In file included from ./OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_model.h:5: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_init_fmu.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_init_fmu.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_init_fmu.c:1: In file included from ./simulation_data.h:39: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ 2 warnings generated. clang -Os -fPIC -mfpmath=sse -fno-dollars-in-identifiers -I'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/c/fmi' -DOMC_FMI_RUNTIME=1 -DCMINPACK_NO_DLL=1 -c -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_FMU.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_FMU.c In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_FMU.c:9: In file included from ./openmodelica.h:71: In file included from ./gc/../openmodelica_types.h:149: ./gc/omc_gc.h:222:28: warning: expression result unused [-Wunused-value] GC_register_displacement(0); ^ ./gc/omc_gc.h:226:34: warning: expression result unused [-Wunused-value] GC_set_force_unmap_on_gcollect(1); ^ In file included from OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_FMU.c:55: ./fmi-export/fmu2_model_interface.c.inc:79:11: warning: enumeration value 'modelSlaveInitialized' not handled in switch [-Wswitch] switch (comp->state) ^ ./fmi-export/fmu2_model_interface.c.inc:168:16: warning: passing 'char **' to parameter of type 'const char **' discards qualifiers in nested pointer types [-Wincompatible-pointer-types-discards-qualifiers] GC_vasprintf(&str, msg, args); ^~~~ ./gc/../meta/../util/modelica_string.h:71:31: note: passing argument to parameter 'strp' here int GC_vasprintf(const char **strp, const char *fmt, va_list ap); ^ 4 warnings generated. mkdir -p ../binaries/linux64 clang -shared -o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl.so OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_records.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_01exo.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_02nls.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_03lsy.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_04set.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_05evt.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_06inz.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_07dly.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_08bnd.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_09alg.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_10asr.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_11mix.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_12jac.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_13opt.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_14lnz.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_15syn.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_16dae.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_17inl.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_init_fmu.o OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_FMU.o -L"/home/hudson/saved_omc/libraries/.openmodelica/libraries/OpenHydraulics 1.0.0-master/Circuits" -Wl,-Bstatic "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc" "-L/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" -Wl,-rpath="/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/" "-L/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/binaries/Modelica" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/x86_64-linux" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/x86_64-linux" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/linux64" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library/linux64" "-L/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library" -Wl,-rpath="/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.0+maint.om/Resources/Library" -lModelicaExternalC -Wl,-Bdynamic -L'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -Wl,-rpath,'/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc' -lSimulationRuntimeFMI -Wl,--no-as-needed -Wl,--disable-new-dtags -llapack -lblas -lm -lpthread -rdynamic -Wl,--no-undefined /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libModelicaExternalC.a(ModelicaInternal.o): In function `ModelicaInternal_temporaryFileName': ModelicaInternal.c:(.text+0x697): warning: the use of `tmpnam' is dangerous, better use `mkstemp' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionHead_24cushionTableBlock_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x41): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionHead_24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xb1): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionHead_24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xc6): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionRod_24cushionTableBlock_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x142): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionRod_24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x1b2): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1D_24doubleActingCylinder_24cushionRod_24cushionTableBlock_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x1c7): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24cushionRestriction_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x243): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24cushionRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x2b3): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24cushionRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x2c8): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24reliefValve_24variableRestriction_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x344): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x3b4): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionHead_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x3c9): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24cushionRestriction_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x445): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24cushionRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x4b5): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24cushionRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x4ca): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24reliefValve_24variableRestriction_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x546): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x5b6): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24doubleActingCylinder_24cushionRod_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x5cb): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24fVController_24ForceProfile_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x647): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24fVController_24ForceProfile_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x6b7): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24fVController_24ForceProfile_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x6cc): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24fVController_24VelocityProfile_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x748): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24fVController_24VelocityProfile_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x7b8): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24fVController_24VelocityProfile_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x7cd): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24reliefValve_24variableRestriction_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x849): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x8b9): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24reliefValve_24variableRestriction_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x8ce): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24A2T_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x94a): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24A2T_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x9ba): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24A2T_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0x9cf): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24B2T_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xa4b): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24B2T_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xabb): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24B2T_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xad0): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24P2A_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xb4c): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24P2A_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xbbc): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24P2A_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xbd1): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24P2B_24MeteringTable_tableInit': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xc4d): undefined reference to `ModelicaTables_CombiTable1D_init' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `omc_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24P2B_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xcbd): undefined reference to `ModelicaTables_CombiTable1D_interpolate' OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.o: In function `boxptr_Modelica_Blocks_Tables__omcQCombiTable1Ds_24valve4_5F_5F3posOCtandem_24P2B_24MeteringTable_tableIpo': OpenHydraulics_OpenHydraulics_Circuits_OpenCenterForceVelocityControl_functions.c:(.text+0xcd2): undefined reference to `ModelicaTables_CombiTable1D_interpolate' clang: error: linker command failed with exit code 1 (use -v to see invocation) Makefile:57: recipe for target 'nozip' failed make: *** [nozip] Error 1