Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_Unconditioned",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_Unconditioned",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.878/1.878, allocations: 288.2 MB / 303.2 MB, free: 8.129 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00134/0.00134, allocations: 195.3 kB / 371.8 MB, free: 10.28 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.151/2.151, allocations: 205.4 MB / 0.6305 GB, free: 10.02 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001106/0.001105, allocations: 101 kB / 0.7439 GB, free: 5.945 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004927/0.0004927, allocations: 11.16 kB / 0.8669 GB, free: 142.1 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3402/0.3407, allocations: 115.3 MB / 0.9795 GB, free: 27.62 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.729/7.069, allocations: 2.128 GB / 3.108 GB, free: 180.4 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000285/7.07, allocations: 99.95 kB / 3.108 GB, free: 180.3 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned Notification: Performance of FrontEnd: time 6.425/13.49, allocations: 1.633 GB / 4.74 GB, free: 1.613 MB / 0.9792 GB