Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_IdealHeatingCoolingSummer",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_EnergyPlus_Examples_SmallOffice_IdealHeatingCoolingSummer",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.83/1.83, allocations: 288.2 MB / 303.2 MB, free: 8.109 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001375/0.001375, allocations: 174.9 kB / 371.8 MB, free: 10.15 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.204/2.204, allocations: 205.4 MB / 0.6305 GB, free: 10.04 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001044/0.001044, allocations: 91.61 kB / 0.7439 GB, free: 5.953 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004153/0.0004153, allocations: 10.75 kB / 0.8669 GB, free: 142 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2765/0.2769, allocations: 115.3 MB / 0.9795 GB, free: 27.64 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.964/7.241, allocations: 2.132 GB / 3.112 GB, free: 133.5 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0004282/7.242, allocations: 106.6 kB / 3.112 GB, free: 133.4 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/EnergyPlus/BaseClasses/ThermalZoneAdapter.mo:98:3-126:43:writable] Error: Type mismatch for named argument in Buildings.ThermalZones.EnergyPlus.BaseClasses.SpawnExternalObject.constructor(derivatives_delta={}). The argument has type: Integer[0] expected type: Real[nDer] Error: Error occurred while flattening model Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.IdealHeatingCoolingSummer Notification: Performance of FrontEnd: time 7.606/14.85, allocations: 1.633 GB / 4.745 GB, free: 115.8 MB / 0.9948 GB