Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case950FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case950FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.885/1.885, allocations: 288.2 MB / 303.2 MB, free: 8.262 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001279/0.001279, allocations: 181.1 kB / 371.8 MB, free: 10.29 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.888/1.888, allocations: 205.4 MB / 0.6305 GB, free: 10 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0008911/0.000891, allocations: 100.1 kB / 0.7439 GB, free: 5.918 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004259/0.0004259, allocations: 14.91 kB / 0.8669 GB, free: 142 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2552/0.2557, allocations: 115.3 MB / 0.9795 GB, free: 27.58 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.775/7.031, allocations: 2.246 GB / 3.226 GB, free: 51.7 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000757/7.032, allocations: 131.9 kB / 3.226 GB, free: 51.57 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF Notification: Performance of FrontEnd: time 3.111/10.14, allocations: 0.5394 GB / 3.765 GB, free: 178.1 MB / 0.948 GB