Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case900FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case900FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.824/1.824, allocations: 288.2 MB / 303.2 MB, free: 8.191 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001433/0.001433, allocations: 185 kB / 371.8 MB, free: 10.26 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.252/2.252, allocations: 205.4 MB / 0.6305 GB, free: 9.973 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001274/0.001274, allocations: 95.47 kB / 0.7439 GB, free: 5.922 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.000524/0.0005241, allocations: 15.03 kB / 0.8669 GB, free: 142.1 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3653/0.3658, allocations: 115.3 MB / 0.9795 GB, free: 27.58 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.439/6.804, allocations: 2.243 GB / 3.222 GB, free: 17.71 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.000473/6.805, allocations: 119.5 kB / 3.222 GB, free: 17.65 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF Notification: Performance of FrontEnd: time 3/9.805, allocations: 0.533 GB / 3.755 GB, free: 185 MB / 0.948 GB