Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.ThermalZones.Detailed.Examples.FFD.WindowWithShade.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Examples.FFD.WindowWithShade,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_Detailed_Examples_FFD_WindowWithShade",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Examples.FFD.WindowWithShade,fileNamePrefix="Buildings_maint_8_0_x_Buildings_ThermalZones_Detailed_Examples_FFD_WindowWithShade",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.802/1.802, allocations: 288.2 MB / 303.2 MB, free: 8.234 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001301/0.001301, allocations: 181 kB / 371.8 MB, free: 10.29 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.252/2.252, allocations: 205.4 MB / 0.6305 GB, free: 10.01 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009082/0.0009081, allocations: 94.45 kB / 0.7439 GB, free: 5.914 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.000432/0.0004317, allocations: 11.06 kB / 0.8669 GB, free: 142.1 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2602/0.2606, allocations: 115.3 MB / 0.9795 GB, free: 27.61 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.942/7.203, allocations: 2.216 GB / 3.196 GB, free: 83.95 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003333/7.203, allocations: 95.95 kB / 3.196 GB, free: 83.86 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/ThermalZones/Detailed/BaseClasses/RoomHeatMassBalance.mo:151:11-151:27:writable] Error: Type mismatch in binding name = {"North Wall", "South Wall", "Floor", "Ceiling"}, expected subtype of String, got type String[4]. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Examples.FFD.WindowWithShade Notification: Performance of FrontEnd: time 3.104/10.31, allocations: 489.9 MB / 3.674 GB, free: 201.2 MB / 0.948 GB