Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.8.0.x_Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 8.0.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Electrical_AC_ThreePhasesBalanced_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels,fileNamePrefix="Buildings_maint_8_0_x_Buildings_Electrical_AC_ThreePhasesBalanced_Sources_Examples_PVPanels",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/package.mo): time 1.737/1.737, allocations: 288.2 MB / 303.2 MB, free: 8.109 MB / 234.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00121/0.00121, allocations: 183.8 kB / 371.8 MB, free: 10.28 MB / 298.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.763/1.763, allocations: 205.4 MB / 0.6305 GB, free: 10.02 MB / 458.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.000872/0.0008721, allocations: 102.8 kB / 0.7439 GB, free: 5.953 MB / 0.5573 GB Notification: Performance of FrontEnd - loaded program: time 0.0004496/0.0004495, allocations: 15.81 kB / 0.8669 GB, free: 142.2 MB / 0.6198 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3032/0.3037, allocations: 115.3 MB / 0.9795 GB, free: 27.63 MB / 0.6198 GB Notification: Performance of FrontEnd - scodeFlatten: time 5.619/5.923, allocations: 2.105 GB / 3.085 GB, free: 204 MB / 0.948 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003818/5.923, allocations: 103.9 kB / 3.085 GB, free: 203.9 MB / 0.948 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Electrical/Interfaces/Terminal.mo:7:1-7:54:writable] Error: Could not evaluate structural parameter (or constant): PhaseSystem.n which gives dimensions of array: v[PhaseSystem.n]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.Electrical.AC.ThreePhasesBalanced.Sources.Examples.PVPanels Notification: Performance of FrontEnd: time 0.1593/6.083, allocations: 66.88 MB / 3.15 GB, free: 136.8 MB / 0.948 GB