Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF,fileNamePrefix="Buildings_maint_7_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case950FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF,fileNamePrefix="Buildings_maint_7_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case950FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.565/1.565, allocations: 251.9 MB / 266.9 MB, free: 11.04 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001111/0.001111, allocations: 191.6 kB / 326.5 MB, free: 2.266 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.045/2.045, allocations: 205.4 MB / 0.5775 GB, free: 20.3 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001034/0.001034, allocations: 86.36 kB / 0.6821 GB, free: 12.92 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004277/0.0004278, allocations: 6.719 kB / 0.7963 GB, free: 135.1 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.31/0.3105, allocations: 106.3 MB / 0.9002 GB, free: 63.89 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.676/7.986, allocations: 2.365 GB / 3.265 GB, free: 135 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0005699/7.987, allocations: 119.7 kB / 3.265 GB, free: 135 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case950FF Notification: Performance of FrontEnd: time 3.044/11.03, allocations: 0.5331 GB / 3.798 GB, free: 150.6 MB / 0.8855 GB