Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF,fileNamePrefix="Buildings_maint_7_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case900FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF,fileNamePrefix="Buildings_maint_7_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases9xx_Case900FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.527/1.527, allocations: 251.9 MB / 266.8 MB, free: 11.03 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001834/0.001834, allocations: 180 kB / 326.5 MB, free: 2.23 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.542/2.542, allocations: 205.4 MB / 0.5775 GB, free: 20.24 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.001017/0.001017, allocations: 91.89 kB / 0.6821 GB, free: 12.88 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004217/0.0004217, allocations: 8.656 kB / 0.7963 GB, free: 135.2 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.317/0.3175, allocations: 106.3 MB / 0.9002 GB, free: 63.81 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 6.671/6.989, allocations: 2.361 GB / 3.261 GB, free: 214.9 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0006585/6.99, allocations: 124.9 kB / 3.261 GB, free: 214.9 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900FF Notification: Performance of FrontEnd: time 2.021/9.011, allocations: 0.5269 GB / 3.788 GB, free: 22.46 MB / 0.8855 GB