Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,fileNamePrefix="Buildings_maint_7_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600FF",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF,fileNamePrefix="Buildings_maint_7_0_x_Buildings_ThermalZones_Detailed_Validation_BESTEST_Cases6xx_Case600FF",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.591/1.591, allocations: 251.9 MB / 266.9 MB, free: 11.01 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001309/0.001309, allocations: 188.7 kB / 326.5 MB, free: 2.234 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.237/2.237, allocations: 205.4 MB / 0.5775 GB, free: 20.22 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009975/0.0009976, allocations: 86.34 kB / 0.6821 GB, free: 12.89 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0004246/0.0004245, allocations: 9 kB / 0.7963 GB, free: 135 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.307/0.3074, allocations: 106.3 MB / 0.9002 GB, free: 63.81 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 7.996/8.304, allocations: 2.36 GB / 3.26 GB, free: 139.6 MB / 0.8855 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0007223/8.305, allocations: 115.6 kB / 3.26 GB, free: 139.6 MB / 0.8855 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/HeatTransfer/Data/OpaqueConstructions.mo:9:4-11:111:writable] Error: Could not evaluate structural parameter (or constant): nLay which gives dimensions of array: material[nLay]. Array dimensions must be known at compile time. Error: Error occurred while flattening model Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF Notification: Performance of FrontEnd: time 2.659/10.96, allocations: 0.5126 GB / 3.773 GB, free: 147.3 MB / 0.8855 GB