Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Chillers_Validation_Carnot_TEva_reverseFlow",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Chillers_Validation_Carnot_TEva_reverseFlow",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.446/1.446, allocations: 251.9 MB / 266.9 MB, free: 11.01 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.001507/0.001507, allocations: 179.8 kB / 326.5 MB, free: 2.234 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.103/2.103, allocations: 205.4 MB / 0.5775 GB, free: 20.57 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.000952/0.0009519, allocations: 89.36 kB / 0.6821 GB, free: 13.34 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0003564/0.0003566, allocations: 13.16 kB / 0.7963 GB, free: 135 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2335/0.2339, allocations: 106.3 MB / 0.9001 GB, free: 64.23 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 0.9679/1.202, allocations: 414.9 MB / 1.305 GB, free: 1.961 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0003084/1.202, allocations: 90.7 kB / 1.305 GB, free: 1.914 MB / 0.8073 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Chillers/Validation/Carnot_TEva_reverseFlow.mo:22:3-37:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow Notification: Performance of FrontEnd: time 0.1752/1.377, allocations: 82.3 MB / 1.386 GB, free: 11.21 MB / 0.8855 GB