Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries/ --ompython_omhome=/usr Buildings_maint.7.0.x_Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo", uses=false) Using package ModelicaServices with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo) Using package Buildings with version 7.0.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo) Running command: "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Chillers_Validation_Carnot_TEva_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) "" <> buildModelFMU(Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity,fileNamePrefix="Buildings_maint_7_0_x_Buildings_Fluid_Chillers_Validation_Carnot_TEva_LimitedCapacity",fmuType="me",version="2.0",platforms={"static"}) Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/package.mo): time 1.47/1.47, allocations: 251.9 MB / 266.8 MB, free: 11.02 MB / 218.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 3.2.3+maint.om/package.mo): time 0.00133/0.00133, allocations: 187.8 kB / 326.5 MB, free: 2.219 MB / 250.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.102/2.102, allocations: 205.4 MB / 0.5775 GB, free: 20.29 MB / 426.7 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 3.2.3+maint.om/package.mo): time 0.0009938/0.0009939, allocations: 82.41 kB / 0.6821 GB, free: 12.88 MB / 0.5105 GB Notification: Performance of FrontEnd - loaded program: time 0.0003955/0.0003955, allocations: 12.31 kB / 0.7963 GB, free: 135.2 MB / 0.6042 GB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2709/0.2713, allocations: 106.3 MB / 0.9001 GB, free: 63.83 MB / 0.6042 GB Notification: Performance of FrontEnd - scodeFlatten: time 1.08/1.352, allocations: 414.8 MB / 1.305 GB, free: 1.539 MB / 0.8073 GB Notification: Performance of FrontEnd - mkProgramGraph: time 0.0002708/1.352, allocations: 90.39 kB / 1.305 GB, free: 1.492 MB / 0.8073 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 7.0.3-maint.7.0.x/Fluid/Chillers/Examples/Carnot_TEva.mo:19:3-33:70:writable] Error: Variable chi: Cyclically dependent constants or parameters found in scope Buildings.Fluid.Chillers.Carnot_TEva$chi: {COP_nominal,etaCarnot_nominal} (ignore with -d=ignoreCycles). Error: Error occurred while flattening model Buildings.Fluid.Chillers.Validation.Carnot_TEva_LimitedCapacity Notification: Performance of FrontEnd: time 0.1871/1.539, allocations: 83.74 MB / 1.387 GB, free: 9.52 MB / 0.8855 GB